I bought 10 of these batteries. All of them arrived with no imperfections, with a charge of 3.48 V and weighting around 46 g.
Ships from Stockbridge, GA · Most in-stock orders ship within 1 business day · Call 1-800-547-3050
Wholesale and bulk pricingMost in-stock orders ship within 1 business dayCall 1-800-547-3050Wholesale and bulk pricing
Call or text a person
Call 1-800-547-3050Text 1-833-419-2192support@18650batterystore.comMonday to Friday, 9 AM to 5 PM Eastern
Other sizes
Other sizes: see allCell sizes
Household sizes
Which size do I have?
The number is the size. An 18350 is 18 mm across and 35 mm long; a 26650 is 26 mm across and 65 mm long.
18650 sizing explainedCan't find your size? Call 1-800-547-3050
Learn
Learn: overviewAn 18650 lithium-ion cell rated 3,000 mAh minimum and 3,120 mAh nominal, at 0.2ItA to 2.0 V after a standard charge [1][2], with two continuous discharge ratings: 15 A “(Without 80 deg temperature cut)” and 30 A “(With 80 deg temperature cut)” [1]. Below: every rating with its condition, Murata’s own curves digitized, and what we calculated from them, so you can check each number.
A bare cell: a component for protected packs and devices built for it. Not for vaping. Charge on a lithium-ion (Li-ion) charger that stops at 4.2 V.
01SPEC PLATE
Two documents describe this cell. The ratings come from Sony’s 15-page Product Specifications [1], Ver. 0.1 of 2015, a tentative engineering specification for pack makers. It is marked [Confidential] and Tentative, so we quote it but don’t post it. Murata’s one-page data sheet [2], Version 001, is public and linked above: it prints the capacities, nominal voltage, mass and size, and four charts, but no current, voltage or temperature limits. Where they overlap they agree. Then come figures we read from the data sheet’s charts, our arithmetic, and facts from the safety data sheet (SDS) [3] and the UN38.3 transport test reports [4][5]. Each row names its source or shows its formula.
| SPECIFICATION | VALUE | CONDITION · SOURCE |
|---|---|---|
| RATED · MANUFACTURER copied from specification [1] and data sheet [2] | ||
| MODEL CODE | US18650VTC6 | as printed [1][2]; designation INR19/66 [1] §1.4 |
| CAPACITY, RATED | 3,000 mAh | “Rated Capacity”: “Discharge at 0.2ItA,2.0Vcutoff after Standard Charge” [1] §2.1; “Rated (minimum) Capacity*” [2] |
| CAPACITY, NOMINAL | 3,120 mAh | same condition [1] §3.1; “Nominal Capacity*” [2]; no capacity is labeled typical |
| NOMINAL VOLTAGE | 3.6 V | [1] §3.2, [2]; “Average Operating Voltage” in [3] |
| CHARGE VOLTAGE | 4.20 V | “Charge Voltage” [1] §3.3; standard charge at 4.20V( +/- 0.005V) [1] §5.3 |
| MAXIMUM CHARGE VOLTAGE | 4.25 V | “Maximum Charge Voltage” [1] §2.2: an upper limit, 4.20V above 45℃ cell surface and 4.15V in condition B below 10℃ [1] §2.8.1; use a charger that stops at 4.2 V |
| CUT OFF VOLTAGE | 2.0 V | “Cut Off Voltage” [1] §2.3, the end of the 0.2ItA capacity discharge; see the next row |
| DISCHARGE, AVOID BELOW | 2.5 V | “*It shall avoid less than 2.5V by discharging.” [1] §8.2.2; the 3.0A, 10A and 15A capacity clauses end at 2.5V [1] §5.5.3 |
| STANDARD CHARGE | 3.0 A | CC-CV at 4.20V( +/- 0.005V) for 2.5 hours, 23 +/-2℃ [1] §5.3; “CCCV, 3.0 A, 4.2 V, 2.5 h, at 23deg.C” [2] |
| CONTINUOUS MAXIMUM CHARGE | 5.0 A | “Continuous” [1] §2.4; 5.00A maximum only from 10 to 60℃ cell surface, 2.00A or 4.00A from 0 to 10℃ [1] §2.8.1 (fig 5.4); the pulse figure in the same row is left out |
| CONTINUOUS MAX. DISCHARGE, NO CUT | 15 A | “(Without 80 deg temperature cut)” [1] §2.5 |
| CONTINUOUS MAX. DISCHARGE, 80 °C CUT | 30 A | “(With 80 deg temperature cut)” [1] §2.5; “Discharge at cell surface temperature below 80℃.” [1] §2.8.2; pack over-temperature protection to operate discharging “until 80degC.(Including overshoot).” [1] §8.2.4.4 |
| CHARGE TEMPERATURE | 0 to 60 °C | “0~+60℃” [1] §2.6, “Allowable Environment Temperature”; above 45℃ cell surface only at 4.20V, 5.00A maximum, 2.00A recommended [1] §2.8.1; the SDS prints 0 to 45 °C (plate below) |
| DISCHARGE TEMPERATURE | −20 to 60 °C | “-20~+60℃”, “Allowable Environment Temperature” [1] §2.6; the same range in [3] §7 |
| CELL SURFACE, DISCHARGE | < 80 °C | “Discharge at cell surface temperature below 80℃.” [1] §2.8.2 |
| AC IMPEDANCE | 8–18 mΩ | “8mΩ~18mΩ” at 1kHz, after standard charge within 3 days, and as shipped [1] §5.5.2; no DC resistance printed |
| ENERGY DENSITY | 631 Wh/l | as printed in the Nominal column [1] §3.4; basis not printed |
| AS SHIPPED | 3.25–3.65 V | open-circuit voltage, within 0.04V on the same cell lot [1] §5.5.1; “About 75% discharged.” [1] §2 |
| DIAMETER | 18.35 mm | +0.15 / −0.20 mm, crimp and trunk [1] §4.1; “Max. 18.5 mm”, with tube [2] |
| HEIGHT | 65.00 mm | ± 0.2 mm [1] §4.1; “Max. 65.2mm” [2] |
| MASS | 46.6 g | ± 1.5 g [1] §2.7; 46.6 g “Weight (typical)” [2] |
| SHAPE · TUBE | Cylindrical · with tube | [2]; tube material and color not printed |
| TERMINAL · PROTECTION | Flat top · none | as sold: bare cell, no protection circuit; the outline in [1] shows a “Flat portion” (φ7.4) at the positive end and names no terminal style |
| MINIMUMS · SPECIFICATION electrical performance, cycle and storage, as printed [1] §5.5 | ||
| MINIMUM AT 0.2ItA | 3,000 mAh | 600mA to 2.0V after standard charging [1] §5.5.3.1 |
| MINIMUM AT 3.0 A | 2,850 mAh | “Standard discharging”, 3.0A to 2.5V, after standard charging [1] §5.5.3.2 |
| MINIMUM AT 10 A | 2,700 mAh | to 2.5V after standard charging [1] §5.5.3.3 |
| MINIMUM AT 15 A | 2,400 mAh | to 2.5V after standard charging [1] §5.5.3.4 |
| MINIMUM AT −10 °C | 1,890 mAh | 10A to 2.5V after standard charging, discharged at −10℃ [1] §5.5.7 |
| MINIMUM AT 0 °C | 2,160 mAh | 10A to 2.5V after standard charging, discharged at 0℃ [1] §5.5.7 |
| AFTER A 0 °C CHARGE | 2,423 mAh | charged 4.20V, 3.00A, 2.5h at 0℃, then standard discharging [1] §5.5.8 |
| CYCLE LIFE | ≥ 1,600 mAh | after 300cycles: charge 4.2V, 4.0A, cut-off 100mA; discharge 10A to 2.5V [1] §5.5.4; no percent basis printed |
| AFTER 28 DAYS AT 45 °C | 2,295 mAh | remaining, 10A to 2.5V, from standard charge; 2,430 mAh recovered after a standard charge [1] §5.5.5 |
| AFTER 365 DAYS AT 23 °C | 2,430 mAh | recovered: standard charge, then 10A to 2.5V [1] §5.5.6 |
| + Source: [1] Sony Energy Devices Corporation, Product Specifications (Tentative), SONY parts name US18650VTC6, Ver. 0.1, 2015.06.30 (1st issue, as printed; the Spec. No. field holds a placeholder); on file since 2020-11-10; not posted, as Sony marks it [Confidential] and Tentative. Questions about its figures: call or text us + Source: [2] Murata Manufacturing Co., Ltd., Cylindrical Type Lithium Ion Secondary Battery US18650VTC6, Version 001 (no date printed); on file 2026-10-20 · Data sheet PDF | ||
| SPECIFICATION | VALUE | CONDITION · SOURCE |
|---|---|---|
| READ FROM DATA-SHEET CHARTS traced from the raster chart images in [2]; reading error about ±20 mAh, ±0.02 V (±0.03 V on the temperature chart) and ±1 °C | ||
| CAPACITY AT 3 A | 3,018 mAh | to 2.5 V, ambient 23deg.C, after a 4.2V/3.0A/150mA charge [2] |
| CAPACITY AT 15 A | 2,982 mAh | to 2.5 V; cell surface about 75 °C at the end [2] |
| CAPACITY AT 20 A | 2,209 mAh | ended by the 80deg.C cut at 3.12 V [2] |
| CAPACITY AT 30 A | 1,298 mAh | ended by the 80deg.C cut at 3.15 V [2] |
| CAPACITY AT −20 °C | 2,917 mAh | 10 A to 2.5 V, charged at 23deg.C; 99 % of the 23 °C curve [2] |
| CHARGE, CONSTANT-CURRENT STAGE | 2,579 mAh | at 3.0 A until 4.2 V; 3,052 mAh in all at the 150mA cut [2] |
| CAPACITY AT CYCLE 300 | 2,271 mAh | 4A charge, 10A discharge, “2.5V or 75deg.C cut-off”, 23deg.C; 2,066 mAh at cycle 500 [2] |
| CALCULATED arithmetic on [1] and [2], shown so you can check it | ||
| 1C (1 ItA) | 3.0 A | 600mA ÷ 0.2, from “0.2ItA(600mA)” [1] §5.5.3.1 and “0.2 ItA (600 mA)” [2] |
| CONTINUOUS DISCHARGE AS C-RATE | 5C · 10C | 15 A “(Without 80 deg temperature cut)” ÷ 3.0 A; 30 A “(With 80 deg temperature cut)” ÷ 3.0 A [1] §2.5 |
| CONTINUOUS CHARGE AS C-RATE | 1.7C | 5.0 A “Continuous” [1] §2.4 ÷ 3.0 A; only from 10 to 60℃ cell surface [1] §2.8.1 |
| ENERGY AT 3 A | 10.74 Wh | ∫V dQ along the 3 A curve to 2.5 V [2] |
| ENERGY AT 30 A | 4.22 Wh | ∫V dQ along the 30 A curve, to the 80deg.C cut [2] |
| AVERAGE POWER AT 30 A | 98 W | 30 A × 3.25 V average of that curve [2]; a test at the 30 A “(With 80 deg temperature cut)” rating [1] |
| CHARGE TIME, 3.0 A TEST | 78 min | t = ∫dQ ÷ I along the current trace [2]: 52 min at 3.0 A, then the taper to the 150mA cut |
| ENERGY, NOMINAL ARITHMETIC | 11.23 Wh | 3.6 V × 3,120 mAh [1] §3.1–3.2; [3] prints 11.3 Wh |
| VOLUME | 17.5 cm³ | π × (18.5 ÷ 2)² × 65.2 mm³, the maximum size with tube [2] |
| FROM THE SAFETY DATA SHEET (SDS) AND UN38.3 TRANSPORT TEST REPORTS copied as printed from [3], [4] and [5] | ||
| CHEMISTRY | Li-ion | “Lithium-Ion Rechargeable Battery” [1] §1.2; the SDS lists “Lithium Nickel Cobalt Oxides”, 38% [3] §3 |
| ENERGY · SDS | 11.3 · 10.8 Wh | “Watt-hour rating”, “11.3 Wh / 10.8 Wh (Nominal / Rated)” [3] §3 |
| ENERGY · UN38.3 | 10.8 Wh | “Watt-hour rating”, with 3.6 V and 3000 mAh rated [4] |
| CHARGE TEMPERATURE · SDS | 0 to 45 °C | “Charge within the limits of 0°C to 45°C (32°F to 113°F) temperature.” [3] §7; [1] prints “0~+60℃” |
| STORAGE · SDS | −20 to 45 °C | “Store within the recommended limit of -20°C to 45°C (-4°F to 113°F), well-ventilated area.” [3] §7 |
| MASS · UN38.3 TEST CELLS | 46.36–46.47 g | the 10 cells weighed before T1 [4]; not our lot |
| TRANSPORT | UN3480 | “UN number” [3] §3; UN3481 when packed with or installed in equipment [3] §14 |
| UN38.3 | QA-7231 | OK for T1–T6 and T8; T7 not applicable to a cell; Tohoku Murata’s own certification, 2017/09/01, of tests run 2015/07/14~2015/07/29 [4]; Sony’s QA-C5111 reports the same run [5] |
| SAFETY DATA SHEET | TMM-TR-A26048 | Date Prepared Jan. 01, 2026; no version printed; Tohoku Murata [3] |
| + Source: [1] Sony Energy Devices Corporation, Product Specifications (Tentative), SONY parts name US18650VTC6, Ver. 0.1, 2015.06.30 (1st issue, as printed; the Spec. No. field holds a placeholder); on file since 2020-11-10; not posted, as Sony marks it [Confidential] and Tentative. Questions about its figures: call or text us + Source: [2] Murata Manufacturing Co., Ltd., Cylindrical Type Lithium Ion Secondary Battery US18650VTC6, Version 001 (no date printed); on file 2026-10-20 · Data sheet PDF + Source: [3] Tohoku Murata Manufacturing Co., Ltd., Safety Data Sheet No. TMM-TR-A26048, Model Name US18650VTC6, Date Prepared Jan. 01, 2026 (no version printed); on file 2026-10-20 · SDS PDF + Source: [4] Tohoku Murata Manufacturing Co., Ltd., Lithium-ion (polymer) rechargeable cell or battery Certification No. QA-7231, Murata model name US18650VTC6, dated 2017/09/01, cell tests 2015/07/14~2015/07/29, to the UN Manual of Tests and Criteria 5th revised edition Amendment 2, Part Ⅲ, subsection 38.3; signed by its own Quality Assurance Department; on file 2026-10-20 · UN38.3 report PDF + Source: [5] Sony Energy Devices Corporation, Lithium-ion (polymer) rechargeable cell or battery Certification No. QA-C5111, US18650VTC6, dated 2015/10/07, the same cell tests (2015/07/14~2015/07/29); signed by its own Quality Assurance Department; on file, not posted: [4] restates its cell results, and [4] is the copy we post | ||
Black marks: voltages as printed in [1], each with its label. Orange bar: where the middle 80 % of capacity is delivered at 3 A, 3.09–3.96 V, read from the 3 A curve traced from [2]. The scale runs from 1.8 to 4.6 V.
Currents as rated in [1], each with its printed condition. C-rates against 1C = 3.0 A, from “0.2ItA(600mA)”. The 30 A rating holds only with the 80 °C cut; without it the rating is 15 A. [1] prints no pulse discharge rating; the pulse figure beside the 5.0A charge rating is left out.
Operating ranges as printed, in °C. Orange: 0 to 45 °C, the charge range both [1] and [3] allow. [1] §8.4 also says “*Do not use the battery in a place of high temperature (60degC or more).” Last row: the test temperatures of the data sheet’s discharge-temperature chart (section 04 below); 75 °C is above the rated discharge range.
Each document’s capacity figures, as printed, on a 2,900–3,200 mAh scale; the axis doesn’t start at zero. All four agree: 3,000 mAh rated (minimum) and 3,120 mAh nominal, at 0.2ItA (600 mA) to 2.0 V after a standard charge [1][2]. None labels a capacity figure typical.
Energy figures in Wh on a 10.4–11.6 Wh scale. 10.8 Wh is 3.6 V × 3.0 Ah, the rated capacity [3][4]. 3.6 V × 3.12 Ah gives 11.23 Wh, not the 11.3 Wh [3] prints, and [3] doesn’t print its basis. [1] and [2] print no Wh. Our integration of the 3 A curve is the last row; it ends at 2.5 V, not 2.0 V. Shipping paperwork follows the SDS.
Mass in grams on a 44.5–48.5 g scale. Top bar: the 45.1–48.1 g band that 46.6 ± 1.5 g allows [1]. Bottom bar: the range of the 10 cells weighed before UN38.3 test T1 in 2015 [4], a maker sample, not our lot. The SDS prints no mass [3].
The data sheet’s lowest and highest discharge currents, digitized. At 3 A the cell runs to 2.5 V and delivers about 3,018 mAh. At 30 A the discharge ends after about 1,298 mAh, still at 3.15 V, when the cell surface reaches 80 °C: the chart’s “2.5Vcut or 80deg.C cut”. That is the cut the 30 A rating needs, “(With 80 deg temperature cut)”; without it the rating is 15 A “(Without 80 deg temperature cut)” [1] §2.5.
Data: digitized from [2] “Discharge characteristics by discharge late” · 3 A and 30 A · charge “4.2V/3.0A/150mAcut” · discharge CC to “2.5Vcut or 80deg.C cut” · ambient 23deg.C · traced from the raster chart images in [2]; reading error about ±20 mAh, ±0.02 V (±0.03 V on the temperature chart) and ±1 °C · data tables under figs 3.1 and 3.2
03BY CURRENT
Six discharge currents from the data sheet, from 3 to 30 A, each with the cell’s surface temperature. Figs 3.1 to 3.5 are read from the charts, fig 3.5 beside the minimums the specification sets at four currents; the rest are arithmetic on the curves, with the formula under each. At 20 and 30 A the 80deg.C cut ends the discharge before 2.5 V.
Data: digitized from [2] “Discharge characteristics by discharge late” · 3 A, 5 A, 10 A · charge “4.2V/3.0A/150mAcut” · discharge CC to “2.5Vcut or 80deg.C cut” · ambient 23deg.C · traced from the raster chart image; reading error about ±20 mAh and ±0.02 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 3 A · 1C | 4.01 | 3.92 | 3.76 | 3.62 | 3.46 | 3.26 | 3,018 | 2.49 | 2.5 V |
| 5 A · 1.7C | 3.95 | 3.86 | 3.71 | 3.56 | 3.41 | 3.22 | 3,004 | 2.50 | 2.5 V |
| 10 A · 3.3C | 3.83 | 3.73 | 3.60 | 3.46 | 3.31 | 3.13 | 2,994 | 2.49 | 2.5 V |
Data: digitized from [2] “Discharge characteristics by discharge late” · 15 A, 20 A, 30 A · charge “4.2V/3.0A/150mAcut” · discharge CC to “2.5Vcut or 80deg.C cut” · ambient 23deg.C · traced from the raster chart image; reading error about ±20 mAh and ±0.02 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 15 A · 5C | 3.73 | 3.62 | 3.50 | 3.37 | 3.24 | 3.07 | 2,982 | 2.48 | 2.5 V |
| 20 A · 6.7C | 3.61 | 3.50 | 3.39 | 3.29 | 3.17 | trace ended | 2,209 | 3.12 | the 80deg.C cut |
| 30 A · 10C | 3.45 | 3.30 | 3.18 | trace ended | trace ended | trace ended | 1,298 | 3.15 | the 80deg.C cut |
Data: digitized from the surface-temperature curves in [2] “Discharge characteristics by discharge late” (right axis, “Surface Temperature [deg.C]”) · charge “4.2V/3.0A/150mAcut” · discharge CC to “2.5Vcut or 80deg.C cut” · ambient 23deg.C · traced from the raster chart image; reading error about ±20 mAh and ±1 °C · dotted line: 80 °C. At 20 and 30 A the surface reaches 80 °C and the discharge stops, as the chart’s condition allows; at 15 A it ends near 75 °C at 2.5 V. These are tests in 23deg.C air; in a pack, neighboring cells add heat.
| SERIES | °C AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | AT END |
|---|---|---|---|---|---|---|---|
| 15 A · 5C | 22 | 35 | 47 | 56 | 62 | 68 | 75 |
| 20 A · 6.7C | 22 | 39 | 54 | 67 | 77 | trace ended | 80 |
| 30 A · 10C | 22 | 45 | 67 | trace ended | trace ended | trace ended | 80 |
Cell surface temperature at the end of each discharge curve in [2] “Discharge characteristics by discharge late”, from 22.5 °C at the start in 23deg.C air; traced from the raster chart image; reading error about ±20 mAh and ±1 °C. Orange: the two discharges the 80deg.C cut ended, at 20 and 30 A. Bars start at zero, on a 0–90 °C scale. [1] §2.5 rates 30 A “(With 80 deg temperature cut)” and 15 A “(Without 80 deg temperature cut)”; [1] §2.8.2 asks for discharge “below 80℃” at the cell surface.
Black: capacity at the end of each curve in [2] “Discharge characteristics by discharge late”: to 2.5 V, or at 20 and 30 A to the 80deg.C cut. Gray: the minimum [1] sets at that current after a standard charge, to 2.5 V (to 2.0 V at 0.2ItA). The chart’s charge (4.2V/3.0A/150mA cut) differs a little from [1]’s standard charge (3.0A for 2.5 hours). [1] sets no minimum at 5, 20 or 30 A.
| CURRENT | C-RATE | CURVE END mAh [2] | CURVE ENDED | MINIMUM mAh [1] | MINIMUM TO |
|---|---|---|---|---|---|
| 0.6 A | 0.2C | no curve | 3,000 | 2.0 V | |
| 3 A | 1C | 3,018 | to 2.5 V | 2,850 | 2.5 V |
| 5 A | 1.7C | 3,004 | to 2.5 V | not printed | |
| 10 A | 3.3C | 2,994 | to 2.5 V | 2,700 | 2.5 V |
| 15 A | 5C | 2,982 | to 2.5 V | 2,400 | 2.5 V |
| 20 A | 6.7C | 2,209 | to the 80deg.C cut | not printed | |
| 30 A | 10C | 1,298 | to the 80deg.C cut | not printed |
Energy = the area under each voltage–capacity curve (∫V dQ), digitized from [2] “Discharge characteristics by discharge late”, to 2.5 V. Orange: 20 and 30 A, whose curves end at the 80deg.C cut. Printed for comparison: 10.8 Wh rated and 11.3 Wh nominal [3].
Cell voltage after the same capacity delivered, read from each curve in [2]; depths stop at 1,200 mAh because the 30 A curve ends at 1,298 mAh. At 700 mAh the 30 A curve sits 0.62 V below the 3 A curve: 0.62 V ÷ 27 A ≈ 23 mΩ (21–23 mΩ across the three depths). Effective resistance = (V at 3 A − V at 30 A) ÷ (30 − 3) A at the same capacity delivered; arithmetic, not a rating. [1] prints only an AC impedance, 8–18 mΩ at 1 kHz, a different measurement; the 30 A cell also heats to 80 °C during the test (fig 3.3).
| DEPTH | 3 A | 5 A | 10 A | 15 A | 20 A | 30 A | mΩ, 3 → 30 A |
|---|---|---|---|---|---|---|---|
| 300 mAh | 3.96 | 3.90 | 3.78 | 3.67 | 3.56 | 3.37 | 22 |
| 700 mAh | 3.86 | 3.81 | 3.68 | 3.57 | 3.46 | 3.24 | 23 |
| 1,200 mAh | 3.71 | 3.65 | 3.55 | 3.45 | 3.35 | 3.16 | 21 |
Power = current × average voltage of each digitized curve in [2], over the whole discharge: to 2.5 V, or for the orange 20 and 30 A rows to the 80deg.C cut. The start of a discharge runs higher, the end lower.
Runtime = capacity delivered ÷ current, from the curves in [2], from a 4.2V/3.0A/150mA charge in 23deg.C air. Orange: 20 and 30 A, where the 80deg.C cut ended the discharge before 2.5 V. A device whose average draw is below its peak current runs longer than the figure at that peak.
Each point is one digitized curve from [2] “Discharge characteristics by discharge late”: energy delivered against average power, power on a log scale. Orange points: 20 and 30 A, ended by the 80deg.C cut. The energy falls steeply above 15 A because those discharges stop at 80 °C, not at 2.5 V.
| CURRENT | AVERAGE W | ENERGY Wh | RUNTIME | ENDED AT |
|---|---|---|---|---|
| 3 A · 1C | 10.7 | 10.74 | 1 h 00 min | to 2.5 V |
| 5 A · 1.7C | 17.5 | 10.54 | 36 min | to 2.5 V |
| 10 A · 3.3C | 34.1 | 10.21 | 18 min | to 2.5 V |
| 15 A · 5C | 49.9 | 9.92 | 12 min | to 2.5 V |
| 20 A · 6.7C | 67.2 | 7.42 | 6.6 min | to the 80deg.C cut |
| 30 A · 10C | 97.6 | 4.22 | 2.6 min | to the 80deg.C cut |
04BY TEMPERATURE
Eight test temperatures from −20 to 75 °C, digitized from the data sheet, all at 10 A after a charge at 23 °C. The chart’s condition line reads “-30deg.C to 75deg.C”, but its legend and curves stop at −20 °C, so the figures follow the legend. The chart doesn’t say whether these are ambient or cell temperatures. [1] rates discharge at “-20~+60℃” (§2.6) and sets minimums at −10, 0, 23 and 45 °C (§5.5.7).
Data: digitized from [2] “Discharge characteristics by temperature” · charge “23deg.C 4.2V/3A(cc/cv)/150mAcut” · discharge 10 A CC to “2.5Vcut or 80deg.C” at each temperature · the chart doesn’t say whether the temperatures are ambient or cell temperatures · traced from the raster chart image; reading error about ±20 mAh and ±0.03 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 23 °C | 3.84 | 3.74 | 3.60 | 3.46 | 3.31 | 3.13 | 2,960 | 2.49 | 2.5 V |
| 45 °C | 3.92 | 3.81 | 3.65 | 3.51 | 3.36 | 3.15 | 2,954 | 2.49 | 2.5 V |
| 60 °C | 3.94 | 3.84 | 3.68 | 3.53 | 3.37 | 3.16 | 2,740 | 2.96 | the 80deg.C cut |
Data: digitized from [2] “Discharge characteristics by temperature” · charge “23deg.C 4.2V/3A(cc/cv)/150mAcut” · discharge 10 A CC to “2.5Vcut or 80deg.C” at each temperature · the chart doesn’t say whether the temperatures are ambient or cell temperatures · traced from the raster chart image; reading error about ±20 mAh and ±0.03 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 23 °C | 3.84 | 3.74 | 3.60 | 3.46 | 3.31 | 3.13 | 2,960 | 2.49 | 2.5 V |
| 75 °C | 3.95 | 3.86 | trace ended | trace ended | trace ended | trace ended | 973 | 3.70 | the 80deg.C cut |
Data: digitized from [2] “Discharge characteristics by temperature” · charge “23deg.C 4.2V/3A(cc/cv)/150mAcut” · discharge 10 A CC to “2.5Vcut or 80deg.C” at each temperature · the chart doesn’t say whether the temperatures are ambient or cell temperatures · traced from the raster chart image; reading error about ±20 mAh and ±0.03 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 10 °C | 3.73 | 3.67 | 3.56 | 3.41 | 3.27 | 3.09 | 2,951 | 2.49 | 2.5 V |
| 0 °C | 3.61 | 3.61 | 3.52 | 3.38 | 3.23 | 3.06 | 2,948 | 2.49 | 2.5 V |
| −10 °C | 3.43 | 3.55 | 3.47 | 3.34 | 3.20 | 3.02 | 2,930 | 2.49 | 2.5 V |
Data: digitized from [2] “Discharge characteristics by temperature” · charge “23deg.C 4.2V/3A(cc/cv)/150mAcut” · discharge 10 A CC to “2.5Vcut or 80deg.C” at each temperature · the chart doesn’t say whether the temperatures are ambient or cell temperatures · traced from the raster chart image; reading error about ±20 mAh and ±0.03 V
| SERIES | V AT 100 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V | ENDED AT |
|---|---|---|---|---|---|---|---|---|---|
| 23 °C | 3.84 | 3.74 | 3.60 | 3.46 | 3.31 | 3.13 | 2,960 | 2.49 | 2.5 V |
| −20 °C | 3.17 | 3.47 | 3.41 | 3.29 | 3.16 | 2.98 | 2,917 | 2.49 | 2.5 V |
Data: digitized from the surface-temperature curves in [2] “Discharge characteristics by temperature” (right axis) · 10 A · traced from the raster chart image; reading error about ±20 mAh and ±1 °C · dotted line: 80 °C. The cell warms itself: at −20 °C the surface ends near 35 °C. At 60 °C (and at 75 °C) it reaches 80 °C and the discharge stops. The data table lists all eight curves; the surface lines run slightly past the voltage lines’ ends, as printed.
| SERIES | °C AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | AT VOLTAGE END |
|---|---|---|---|---|---|---|---|
| 75 °C | 73 | 77 | trace ended | trace ended | trace ended | trace ended | 80 |
| 60 °C | 59 | 64 | 67 | 72 | 75 | 78 | 80 |
| 45 °C | 44 | 50 | 55 | 60 | 63 | 66 | 71 |
| 23 °C | 22 | 31 | 38 | 44 | 48 | 51 | 56 |
| 10 °C | 10 | 21 | 29 | 35 | 40 | 44 | 49 |
| 0 °C | 0 | 15 | 24 | 30 | 35 | 39 | 44 |
| −10 °C | −10 | 9 | 19 | 26 | 31 | 35 | 39 |
| −20 °C | −20 | 5 | 16 | 22 | 27 | 31 | 35 |
Black: end capacity of each temperature curve in [2], 10 A to 2.5 V, or to the 80deg.C cut at 60 and 75 °C. Gray: the minimum [1] sets at −10, 0, 23 and 45 °C, also 10A to 2.5V after a standard charge. [1] rates discharge from −20 to 60 °C, so 75 °C is a test point, not a rating.
| TEMPERATURE | CURVE END mAh [2] | % OF 23 °C | CURVE ENDED | MINIMUM mAh [1] |
|---|---|---|---|---|
| 75 °C | 973 | 33 | to the 80deg.C cut | not printed |
| 60 °C | 2,740 | 93 | to the 80deg.C cut | not printed |
| 45 °C | 2,954 | 100 | to 2.5 V | 2,700 |
| 23 °C | 2,960 | 100 | to 2.5 V | 2,700 |
| 10 °C | 2,951 | 100 | to 2.5 V | not printed |
| 0 °C | 2,948 | 100 | to 2.5 V | 2,160 |
| −10 °C | 2,930 | 99 | to 2.5 V | 1,890 |
| −20 °C | 2,917 | 99 | to 2.5 V | not printed |
Average voltage = energy ÷ capacity for each digitized temperature curve in [2], at 10 A. The line joins the eight curves. Orange point: 23 °C. The 60 and 75 °C averages are over shorter discharges, ended by the 80deg.C cut, so they sit high. Lower voltage at the same current means less power and more heat.
| TEMPERATURE | CAPACITY mAh | % OF 23 °C | ENERGY Wh | AVERAGE V | ENDED AT |
|---|---|---|---|---|---|
| 75 °C | 973 | 33 | 3.75 | 3.85 | to the 80deg.C cut |
| 60 °C | 2,740 | 93 | 9.74 | 3.55 | to the 80deg.C cut |
| 45 °C | 2,954 | 100 | 10.28 | 3.48 | to 2.5 V |
| 23 °C | 2,960 | 100 | 10.15 | 3.43 | to 2.5 V |
| 10 °C | 2,951 | 100 | 9.98 | 3.38 | to 2.5 V |
| 0 °C | 2,948 | 100 | 9.84 | 3.34 | to 2.5 V |
| −10 °C | 2,930 | 99 | 9.62 | 3.28 | to 2.5 V |
| −20 °C | 2,917 | 99 | 9.40 | 3.22 | to 2.5 V |
Fig 4.2: 75 °C is above the rated discharge range, “-20~+60℃” [1] §2.6; the discharge ended after about 973 mAh at the 80deg.C cut. Fig 4.4: at −20 °C the voltage first dips to about 3.05 V within the first 50 mAh, then recovers to about 3.47 V as the cell warms itself (fig 4.5). The 23 °C curve here ends at about 2,960 mAh; the 10 A curve in fig 3.1, a separate test, ends at about 2,994 mAh.
05CHARGING
The data sheet charts one charge, 3.0 A CC-CV to 4.2 V with a 150mA cut, in 23deg.C air [2], against charge put in rather than time. Figs 5.1 and 5.2 are its traces; fig 5.3 works out the minutes. Figs 5.4 to 5.6 come from the specification and the SDS: charge limits by cell surface temperature, capacity after charging at 0, 23 and 45 °C, and each document’s charge temperature range.
Data: digitized from [2] “Charge characteristics” · “Charge:4.2V/3.0A/150mAcut” · “Ambient temp : 23deg.C” · x axis: charge put in, not time · traced from the raster chart image; reading error about ±20 mAh, ±0.02 V and ±0.02 A · reaches 4.2 V after about 2,579 mAh
| CHARGE | 300 | 900 | 1,500 | 2,100 | 2,500 | 2,700 | 2,900 | 3,000 | END |
|---|---|---|---|---|---|---|---|---|---|
| 3.0 A · 1C | 3.54 | 3.70 | 3.87 | 4.04 | 4.18 | 4.20 | 4.20 | 4.20 | 4.20 |
Data: digitized from [2] “Charge characteristics” · “Charge:4.2V/3.0A/150mAcut” · “Ambient temp : 23deg.C” · x axis: charge put in, not time · traced from the raster chart image; reading error about ±20 mAh, ±0.02 V and ±0.02 A · 3.0 A to about 2,579 mAh, then the taper
| CHARGE | 300 | 900 | 1,500 | 2,100 | 2,500 | 2,700 | 2,900 | 3,000 | END |
|---|---|---|---|---|---|---|---|---|---|
| 3.0 A · 1C | 3.00 | 3.00 | 3.00 | 3.00 | 3.00 | 2.32 | 1.31 | 0.56 | 0.15 at 3,052 |
Minutes to put in each amount, calculated from the current trace digitized from [2]: t = ∫ dQ ÷ I, because the chart plots against charge, not time. 52 min at 3.0 A to 2,579 mAh, then the taper; about 78 min in all (orange) to the 150mA cut at 3,052 mAh. Near the end the current is small, so the ±20 mAh reading error can move the total by several minutes. [1]’s standard charge is timed instead: 3.0A for 2.5 hours (§5.3).
| CHARGE PUT IN | MINUTES | CURRENT A |
|---|---|---|
| 1,000 mAh | 20.0 | 3.00 |
| 2,000 mAh | 40.0 | 3.00 |
| 2,579 mAh | 51.5 | 3.00 |
| 3,000 mAh | 67.7 | 0.56 |
| 3,052 mAh | 78.0 | 0.15 |
Charge conditions by “Temperature Range / Cell Surface Temperature Range”, as printed in [1] §2.8.1, with each range’s upper charging voltage. “At Low Charging Temperature range, condition A and B are both available. Recommended condition is B.” Above 45℃ the upper limit drops to 4.20V and the recommendation to 2.00A. [1] prints no condition below 0℃: don’t charge there. Bars on a 0–5 A scale.
| CELL SURFACE | RANGE | UPPER V | MAXIMUM | RECOMMENDED |
|---|---|---|---|---|
| 0℃≦T<10℃ | condition A | 4.25V | 2.00A | 1.00A |
| 0℃≦T<10℃ | condition B (recommended) | 4.15V | 4.00A | 2.00A |
| 10℃≦T≦45℃ | standard | 4.25V | 5.00A | 3.00A |
| 45℃<T≦60℃ | high | 4.20V | 5.00A | 2.00A |
Minimum capacity after charging at each temperature, as rated in [1] §5.5.8: “Charging:4.20V” “3.00A, 2.5h”, then “Standard Discharging” (3.0A to 2.5V at 23℃). Orange: 0 °C, the lowest charge temperature [1] rates. % of the 3,000 mAh rated capacity is our arithmetic; [1] prints mAh only.
Where charging is allowed, as each document prints it. [1] allows charging from 0 to 60 ℃ and limits it by cell surface temperature (fig 5.4). The SDS prints “Charge within the limits of 0°C to 45°C (32°F to 113°F) temperature.” [3]. Orange: 0 to 45 °C, where both allow charging. Below 0 °C, don’t charge.
06CYCLE LIFE AND STORAGE
One test program from the data sheet: 4 A charge, 10 A discharge, 23 °C, with a 75deg.C cut-off [2]. Then the specification’s minimums: 1,600 mAh or more after 300 cycles at its own conditions, and the capacity kept after storage [1]. The two cycle figures come from different tests, so they sit in separate figures.
Data: digitized from [2] “Cycle life”, left axis “Discharge Capacity [mAh]” · “Charge : 23deg.C, 4.2V, 4A(CC/CV), 150mA cut-off, Rest:30min” · “Discharge : 23deg.C, 10A, 2.5V or 75deg.C cut-off, Rest:60min” · x axis as printed: “Number of cycle” · traced from the raster chart image; reading error about ±2 cycles, ±20 mAh and ±1 °C · the discharge cut-off here is 75deg.C, not the 80 °C of the other charts and of [1] · axis starts at 1,500 mAh · from a data sheet that says it “has only typical specifications” [2]
| TEST | FIRST | 100 | 200 | 300 | 400 | 500 CYCLES |
|---|---|---|---|---|---|---|
| 10 A discharge | 3,031 mAh | 2,608 mAh | 2,409 mAh | 2,271 mAh | 2,159 mAh | 2,066 mAh |
Data: digitized from [2] “Cycle life”, right axis “Max Temperature [deg.C]” · same test as fig 6.1 · traced from the raster chart image; reading error about ±2 cycles, ±20 mAh and ±1 °C · [2] doesn’t say where the temperature is taken · axis starts at 40 °C
| TEST | FIRST | 100 | 200 | 300 | 400 | 500 CYCLES |
|---|---|---|---|---|---|---|
| Max temperature | 54.7 °C | 56.0 °C | 58.4 °C | 60.6 °C | 62.1 °C | 63.0 °C |
Minimum capacity as rated in [1] §5.5; each row’s capacity comes from a 10A discharge to 2.5V. Storage rows start from a standard charge: “remaining” is the first discharge after storage, “recovered” the discharge after a fresh standard charge. Orange: the cycle-life clause, 1,600 mAh or more after 300 cycles of 4.0A charge (100mA cut-off) and 10A discharge. Its conditions differ from fig 6.1’s (4A charge to 150mA, a 75deg.C cut-off, rests), so the two are not one test. A minimum, not a warranty.
Storage temperatures as each document prints them. [1] adds “*The recommendation is DOD(Depth of discharge) 50~80% for long-term storage.”, that is, about 20 to 50 % charge (our arithmetic), and ships cells “About 75% discharged.” [1].
07TRANSPORT TESTS
Tohoku Murata’s certification QA-7231 [4] records OK for T1–T6 and T8 on the US18650VTC6; T7, overcharge, doesn’t apply to a cell. It is the maker’s own Quality Assurance certification, not an independent lab’s, issued in 2017 for tests run in July 2015. Sony’s QA-C5111 [5] reports the same test run. Both name a similar model for the package tests. Their tables also print what each cell did: a 2015 maker sample, not our lot.
Highest surface temperature each cell reached in T5, as printed in [4]: one tick per cell, the bar spans the lowest to the highest. [4] prints no short-circuit resistance or case temperature. T6 impact is the only other test with a temperature column, and it prints “N” there for all 5 cells, not temperatures; T8 prints no temperatures. Every occurrence code is “N”, defined as no rupture, no fire, no disassembly. The same values appear in [5]. A 2015 maker sample, not our lot.
| TEST | CELLS | MAX °C, EACH CELL | RANGE |
|---|---|---|---|
| T5 external short circuit | 10 | 66.2, 84.2, 79.2, 80.9, 81.8, 62.5, 81.8, 80.1, 80.9, 73.6 | 62.5–84.2 |
Open-circuit voltage after each test, as a percent of the voltage before it, printed for each of the 10 cells in [4]: one tick per value. The same 10 cells went through T1 to T4 in turn, starting at 4.193–4.196 V, fully charged. Mass loss was 0.00 % for each cell in each test, against 0.2 % or less. The scale starts at 85 %.
Mass of the 10 cells weighed before T1, as printed in [4]: 46.36–46.47 g (mean 46.41 g, our arithmetic), inside 46.6 ± 1.5 g [1]; 46.6 g typical [2]. The axis starts at 44.8 g.
| CELL | STATE | BEFORE T1 g |
|---|---|---|
| 01 | first cycle, fully charged | 46.46 |
| 02 | first cycle, fully charged | 46.42 |
| 03 | first cycle, fully charged | 46.39 |
| 04 | first cycle, fully charged | 46.43 |
| 05 | first cycle, fully charged | 46.36 |
| 06 | first cycle, fully charged | 46.36 |
| 07 | first cycle, fully charged | 46.41 |
| 08 | first cycle, fully charged | 46.36 |
| 09 | first cycle, fully charged | 46.47 |
| 10 | first cycle, fully charged | 46.47 |
| ITEM | QA-7231 [4], POSTED | QA-C5111 [5], NOT POSTED |
|---|---|---|
| Issued by | Tohoku Murata Manufacturing Co., Ltd., signed by its Quality Assurance Department: the maker’s own certification | Sony Energy Devices Corporation, signed by its Quality Assurance Department: the maker’s own certification |
| Dated | 2017/09/01 | 2015/10/07 |
| Cell tests run | 2015/07/14~2015/07/29, Koriyama site | the same dates and site |
| Rating printed | 3.6 V · 3000 mAh · 10.8 Wh | the same |
| T1–T4: 10 cells, first cycle, fully charged | OK; residual OCV 98.4–100.0 %, mass loss 0.00 % (fig 7.2) | OK; the same per-cell values |
| T5: 10 cells, first cycle, fully charged | OK; surface 62.5–84.2 °C, limit “170℃≧” (fig 7.1) | OK; the same per-cell values |
| T6: 5 cells, first cycle, 50% charged | OK; the temperature column prints “N” for all 5 cells | OK; the same |
| T7 overcharge | not applicable to a cell | not applicable to a cell |
| T8: 20 cells, fully discharged (1–10 first cycle, 11–20 after 50 cycles) | OK; “N” for all 20 cells | OK on the summary page; the occurrence cells for cells 11–20 are blank |
| Package tests | “Murata's similar model name for packing : UST180HLTC5A(AE)”; packed cell US18650VTC5A; 2015/03/16~2015/03/19 | “Sony's similar model name for packing : UST180”, with a Japanese note (standard packing, air); packed cell US18650VT4; 2012/11/28~2012/12/01 |
Copied from the scanned pages of [4] and [5]; the reports print no test parameters (no altitude, temperatures, vibration profile, shock pulse, short-circuit resistance, impact mass, or forced-discharge current and time) and no observation periods. [4] names its package-test model “UST180HLTC5A(AE)” and [5] “UST180”; both package tests were run on other cell models, before the VTC6 cell tests.
| TEST | METHOD, AS PRINTED IN [1] | CRITERIA | SECTION |
|---|---|---|---|
| Heat cycle | 1) Standard charge 2) Heat cycle at 75℃6h←30min→-40℃6h for 10cycles. 3) Storage at 20 +/- 5℃ for 24hours | No leakage, No interception | [1] §5.6.1 |
| Shock (drop) | 1) Standard Charge 2) Drop the battery from 1.2m height onto P-tile for 3 times in each of X, Y and Z direction 3) Discharge at 10A, 2.5V cutoff 4) Standard charge 5) Capacity by discharge at 10A, 2.5V cutoff | No leakage, 2565mAh or more | [1] §5.6.2 |
| Vibration | 1) Standard charge 2) Vibration test under the following condition Frequency and acceleration:10-60Hz, 20.6m/s2 Frequency and acceleration:60-80Hz, 13.7m/s2 Frequency and acceleration:80-100Hz, 6.9m/s2 Frequency and acceleration:100-125Hz,3.9m/s2 3) Discharge at 10A, 2.5V cutoff 4) Standard charge 5) Capacity by discharge at 10A, 2.5V cutoff | No leakage, 2565mAh or more | [1] §5.6.3 |
Methods and criteria as printed in [1] (English text). [1] lists these as tests the cell is specified to meet and prints no results. The UN38.3 results above are a different set of tests, from [4] and [5].
08COMPARE
Nine other 18650 cells, each from its own manufacturer document. A higher discharge rating usually costs capacity. The conditions behind each rating differ, so the table quotes each document’s wording.
Bars show each printed figure, not like-for-like ratings: the P28A, P26A and M35A documents print a maximum discharging current, the others continuous ratings [6]. Orange: the VTC6, from its specification [1]. Its bar shows 30 A, the rating “(With 80 deg temperature cut)”; without the cut it is rated 15 A “(Without 80 deg temperature cut)” [1] §2.5. Bars start at zero: minimum capacity on a 0–3,500 mAh scale, discharge on 0–40 A. The condition sits beside each current. Pulse and other non-continuous figures are left out.
| CELL | TYPICAL OR NOMINAL mAh | MINIMUM mAh | DISCHARGE RATING AS PRINTED | CHARGE RATING AS PRINTED | MASS g |
|---|---|---|---|---|---|
| Molicel P28B INR-18650-P28B |
2,800 typical | 2,650 | “Discharge Current, Continuous: 40 A (80°C cut-off)” | “8.4 A (70°C cut-off)” | 48 max |
|
Molicel P28A INR-18650-P28A |
2,800 typical | 2,700 | “Maximum discharging current 35A (with 80 oC temp. cut)” (cell specification) | “8.4A”, “See Section 4.14” (cell specification) | 48 max |
|
Molicel P26A INR-18650-P26A |
2,600 typical | 2,500 | “Maximum discharging current: 35A” (no condition printed) | “6A” | 48 max |
| Sony/Murata VTC6 US18650VTC6 |
3,120 nominal | 3,000 | “30A” “(With 80 deg temperature cut)” and “15A” “(Without 80 deg temperature cut)”, under “Continuous Maximum Discharge Current” [1] §2.5 | “5.0A” “Continuous” [1] §2.4 (pulse figure not shown) | 46.6 typical |
|
Samsung 30Q INR18650-30Q6 |
3,000 nominal | 2,950 | “Max. continuous discharge: 15A (Without temperature cut) / 30A (With 80℃ temperature cut)” | “Rated charge: CCCV, 4A, 4.20V, 100mA cut-off” | 48 max |
|
Molicel P30B INR-18650-P30B |
3,000 typical | 2,900 | “Discharge Current, Continuous: 30 A (80°C cut-off)” | “9 A (60°C cut-off)” | 47 max |
|
Samsung 25R INR18650-25R |
not printed | 2,500 | “Max. continuous discharge: 20A (@ RT)” | “Rated charge: CCCV, 4A, 4.20V, 100mA cut-off” | 45 max |
| LG HG2 18650HG2 |
3,000 nominal | Not stated by manufacturer | “Max. Discharge Current, For continuous discharge: 20000mA” | “Max. Charge Current: 4000mA” | 48 max |
|
Molicel M35A INR-18650-M35A |
3,450 typical | 3,350 | “Maximum discharging current: 10 A” (no condition printed) | “1.7 A, see Section 4.14” | 48 max |
|
Samsung 35E INR18650-35E |
not printed | 3,350 | “Max. Discharge Current: 8,000mA (for continuous discharge)” (non-continuous figure not shown) | “2,000mA (not for cycle life)” | 50 max |
Text in quotation marks is copied as printed from each manufacturer document, the specification [1] for the VTC6 and documents [6] for the others, newest version in our library, checked by a second reading; notes in parentheses are ours. Links go to the bare-cell listing in our store.
09PACK MATH
How the single-cell ratings scale in series (S) and parallel (P), as far as the 5S2P the specification allows. Illustrative arithmetic, not a pack rating.
charge voltage, 4.20 V [1] §3.3
nominal voltage, 3.6 V [1][2]
Ah rated, 0.2ItA to 2.0 V; 2.7 × P at 10 A to 2.5 V [1] §2.1, §5.5.3.3
A without the 80 deg temperature cut; 30 × P only with it [1] §2.5*
| CONFIG | CELLS | V MAX | V NOMINAL | Ah RATED | Wh RATED | A, WITHOUT 80 DEG CUT* | A, WITH 80 DEG CUT* | CELL MASS g, MAX |
|---|---|---|---|---|---|---|---|---|
| 1S1P | 1 | 4.2 | 3.6 | 3.0 | 10.8 | 15 | 30 | 48 |
| 2S1P | 2 | 8.4 | 7.2 | 3.0 | 21.6 | 15 | 30 | 96 |
| 3S1P | 3 | 12.6 | 10.8 | 3.0 | 32.4 | 15 | 30 | 144 |
| 4S1P | 4 | 16.8 | 14.4 | 3.0 | 43.2 | 15 | 30 | 192 |
| 5S1P | 5 | 21.0 | 18.0 | 3.0 | 54.0 | 15 | 30 | 240 |
| 1S2P | 2 | 4.2 | 3.6 | 6.0 | 21.6 | 30 | 60 | 96 |
| 2S2P | 4 | 8.4 | 7.2 | 6.0 | 43.2 | 30 | 60 | 192 |
| 3S2P | 6 | 12.6 | 10.8 | 6.0 | 64.8 | 30 | 60 | 289 |
| 4S2P | 8 | 16.8 | 14.4 | 6.0 | 86.4 | 30 | 60 | 385 |
| 5S2P | 10 | 21.0 | 18.0 | 6.0 | 108.0 | 30 | 60 | 481 |
The single-cell continuous ratings [1] §2.5 times the parallel count, 15 A “(Without 80 deg temperature cut)” and 30 A “(With 80 deg temperature cut)”. [1] §8.2.6 stops at 2 parallels, so the chart does too. Ceilings before derating, not pack ratings.
* Multiplies a single-cell rating by the number of cells in parallel: 15 A “(Without 80 deg temperature cut)”, or 30 A “(With 80 deg temperature cut)”, which needs a pack that stops discharge before the cell surface reaches 80 ℃ [1] §2.5, §2.8.2. [1] §8.2.6 limits the pack: “The cell configuration in the battery pack is to 2 parallels 5 series at the maximum.”, so the table stops at 5S2P. Wh = 10.8 Wh rated [3][4] × S × P. Mass uses 48.1 g, the 46.6 + 1.5 g upper limit [1] §2.7, and counts cells only. [1] §8.2.4 asks every pack for four protective circuits: overcharge, operating “at less than 4.250V/cell”; over-discharge, at 1.5V/cell to 2.5V/cell; over-current, at less than 5A charging and less than 30A discharging; and over-temperature at the cell surface, discharging “until 80degC.(Including overshoot).”, charging until 60degC and not charging below 0degC. It adds “*Do not combine the different Lot Number cell (the Last 5 letters and figure) into the pack” [1] §8.1. Derate for heat, size the BMS, fusing and interconnects for the derated current. The UN38.3 certification [4] covers the bare cell; a pack you build needs its own UN38.3 testing before it ships as UN3480.
10SIZE AND FIT
Drawn at the data sheet’s maximum, with tube, beside nominal outlines of three common formats. The specification prints 18.35 +0.15 / −0.20 by 65.00 ± 0.2 mm; its upper limits match the data sheet’s maximums.
All outlines drawn to the same scale. The VTC6 at its maximum dimensions with tube [2]; the other outlines are nominal format sizes, for scale only.
| DIMENSION | VALUE | CONDITION |
|---|---|---|
| Diameter | 18.5 mm | “Max. 18.5 mm”, with tube [2]; 18.35 +0.15 / −0.20 mm at the crimp and the trunk, the trunk “(excluding wrinkle on the tube)” [1] §4.1 |
| Height | 65.2 mm | “Max. 65.2mm” [2]; 65.00 ± 0.2 mm [1] §4.1 |
| Mass | 46.6 g | ± 1.5 g [1] §2.7; “Weight (typical)” [2]; 46.36–46.47 g for the 10 cells weighed in [4] |
| Positive end | φ7.4 mm | “Flat portion”, outline drawing [1] §7; as sold, flat top |
| Negative end | φ3 mm | no tab welding at the center: “don’t weld in the renge of φ3 from center” (as printed) [1] §7 |
| Volume | 17.5 cm³ | π × (18.5 ÷ 2)² × 65.2 mm³, the maximum envelope |
Check that your holder or device takes a flat-top cell 65.2 mm long (maximum) [2]. Spot-weld nickel strip for packs, outside the 3 mm circle at the center of the negative end [1] §7; don’t solder to the cell [1] §8.4.
11USE IT RIGHT
What this cell is, and how to use it within its ratings.
Questions? Call 1-800-547-3050 or text 1-833-419-2192 to ask a person.
Each linked file is posted unaltered, as we received it; versions are listed as printed. The specification [1] is on file but not posted: Sony marks it [Confidential] and Tentative. Sony’s certification QA-C5111 [5] is on file but not posted: QA-7231 [4] restates its cell results.
Ships from Stockbridge, GA. Most in-stock orders ship within 1 business day.
12QUESTIONS
Short answers. Where an answer comes from a document, it carries its source; the rest is standard handling practice. Anything else: call 1-800-547-3050 or text 1-833-419-2192.
No. It is a bare flat-top cell with no protection circuit. Use it only in packs with a battery management system (BMS) or in devices built for unprotected cells.
Both, under different conditions [1] §2.5. 15 A is the continuous maximum “(Without 80 deg temperature cut)”. 30 A is the continuous maximum “(With 80 deg temperature cut)”: something has to stop the discharge at 80 °C on the cell surface. [1] asks for discharge “below 80℃” at the cell surface (§2.8.2), and for a pack over-temperature circuit that operates discharging “until 80degC.(Including overshoot).” [1] §8.2.4.4. In a pack that is a temperature sensor on the hottest cell, read by the BMS; in a device, its own cell-temperature cut-off. [1] prints no temperature at which discharge may resume. If you don’t know whether your device has a cut-off, use 15 A. In the data sheet’s own tests the cut ended the 30 A discharge after about 1,298 mAh and the 20 A discharge after about 2,209 mAh (fig 3.2) [2]. Neither document prints a pulse discharge rating.
Both figures are printed, for the same discharge: 0.2ItA (600 mA) to 2.0 V after a standard charge. 3,000 mAh is the rated capacity, a minimum; 3,120 mAh is the nominal capacity [1] §2.1, §3.1, [2]. No document labels a capacity figure typical. To 2.5 V the minimums are lower: 2,850 mAh at 3.0 A, 2,700 mAh at 10 A and 2,400 mAh at 15 A [1] §5.5.3.
The model is the same, US18650VTC6, in every document we hold. The 2015 specification [1] and the 2015 UN38.3 certification [5] are issued by Sony Energy Devices Corporation; the data sheet [2] by Murata Manufacturing Co., Ltd.; the SDS [3] and the 2017 UN38.3 certification [4] by Tohoku Murata Manufacturing Co., Ltd. [4] restates the cell results of [5].
No. The US18650VTC6M has its own specification and is a different model. None of its figures are on this page.
Only within the specification’s limits by cell surface temperature [1] §2.8.1 (fig 5.4). 5.0 A is the continuous maximum, “Continuous” [1] §2.4, from 10 to 60 ℃ cell surface; from 0 to 10 ℃ the maximum is 4.00A at 4.15V (condition B, recommended) or 2.00A at 4.25V (condition A). Above 45 ℃ the upper voltage drops to 4.20V and the recommendation to 2.00A. The standard charge is 3.0 A for 2.5 hours [1] §5.3. Above that, use a charger or BMS that reads cell temperature. [1] also prints a pulse charge figure; it is not a continuous rating, so we leave it out.
A lithium-ion charger with a CC-CV profile (constant current, then constant voltage) that stops at 4.2 V. [1] prints 4.25V as its “Maximum Charge Voltage” (§2.2), an upper limit, not a target. Not a NiMH, LiFePO4 or lead-acid charger.
The documents differ. The specification allows charging from 0 to 60 ℃, “0~+60℃”, and above 45 ℃ cell surface only at 4.20V, 5.00A maximum, 2.00A recommended [1] §2.6, §2.8.1. The SDS says “Charge within the limits of 0°C to 45°C (32°F to 113°F) temperature.” [3] §7. Both allow 0 to 45 °C, so charge there.
Runtime ≈ capacity ÷ current. From the data-sheet curves, from full in 23deg.C air: about 1 h 00 min at 3 A, 18 min at 10 A and 12 min at 15 A, to 2.5 V; at 30 A about 2.6 min, until the 80deg.C cut (fig 3.9) [2]. For your own draw, divide 2,400 mAh, the minimum at 15 A to 2.5 V [1] §5.5.3.4, by your current in mA to get hours: at 5 A, 2,400 ÷ 5,000 = 0.48 h, about 29 min.
Little, in the data sheet’s temperature chart: after a charge at 23 °C, at 10 A, the cell delivered about 2,948 mAh at 0 °C and 2,917 mAh at −20 °C, against 2,960 mAh at 23 °C [2], warming itself as it ran (fig 4.5). The chart doesn’t say whether those are air or cell temperatures. The specification’s minimums are lower: 2,160 mAh at 0 °C and 1,890 mAh at −10 °C, at 10 A [1] §5.5.7. Voltage also drops in the cold (figs 4.4 and 4.7), so a device may cut off early. Don’t charge below 0 °C.
Two documents answer differently, at different conditions. The data sheet’s chart, 4 A charge and 10 A discharge with a 75deg.C cut-off at 23 °C, reads about 2,271 mAh at cycle 300 and 2,066 mAh at cycle 500 (fig 6.1) [2]. The specification rates 1,600 mAh or more after 300 cycles of 4.0A charge (100mA cut-off) and 10A discharge to 2.5V [1] §5.5.4. Neither gives an end-of-life cycle count. Heat, current, depth of discharge and storage all change the result.
No. It is a bare cell: a component for protected packs and devices built for it, not for vaping.
No: “*Do not solder leads directly to the battery body.” [1] §8.4. Spot-weld nickel strip, outside the 3 mm circle at the center of the negative end [1] §7, or use a holder.
No, not in the same pack. [1] says “*Do not combine the different Lot Number cell (the Last 5 letters and figure) into the pack” (§8.1). Use cells of one model and lot, at the same state of charge. In series, the weakest cell reaches 2.5 V first and limits the whole pack.
In a case, away from metal objects, somewhere dry. The specification recommends 20degC and humidity 50% or less, “free from high temperature (45degC or more)”, and a depth of discharge of 50~80% for long-term storage, about 20 to 50 % charge [1] §8.3. The SDS gives “-20°C to 45°C” [3] §7. Check the voltage every few months.
As UN3480, lithium-ion batteries, under the SDS [3]. The UN38.3 certification we post, QA-7231 [4], is the maker’s own, for the bare cell. A pack built from these cells needs its own UN38.3 testing.
13SOURCES
Where every number on this page comes from.