Painless experience here as always.
Ships from Stockbridge, GA · Most in-stock orders ship within 1 business day · Call 1-800-547-3050
Wholesale and bulk pricingMost in-stock orders ship within 1 business dayCall 1-800-547-3050Wholesale and bulk pricing
Call or text a person
Call 1-800-547-3050Text 1-833-419-2192support@18650batterystore.comMonday to Friday, 9 AM to 5 PM Eastern
Other sizes
Other sizes: see allCell sizes
Household sizes
Which size do I have?
The number is the size. An 18350 is 18 mm across and 35 mm long; a 26650 is 26 mm across and 65 mm long.
18650 sizing explainedCan't find your size? Call 1-800-547-3050
Learn
Learn: overviewAn 18650 power cell rated 2,800 mAh typical and 2,700 mAh minimum [1][2], with a 35 A maximum discharge and an 80 °C cut-off [2]. Below: every rating with its condition, Molicel’s own curves digitized, and what we calculated from them, so you can check each number.
A bare cell: a component for protected packs and devices built for it. Not for vaping. Charge on a lithium-ion (Li-ion) charger that stops at 4.2 V.
01SPEC PLATE
Molicel publishes two documents for this cell. The one-page data sheet [1] is public and linked above. The 13-page cell specification [2], Ver. 1.2 of 2024, is the engineering document Molicel issues to its direct customers. It adds conditions and minimums the data sheet leaves out, such as the 80 °C cut-off on 35 A and the limits on charge current by temperature. It is marked confidential, so we quote it but don’t post it. Where the two differ, the row shows both. Then come figures we read from the data sheet’s charts, our arithmetic, and facts from the safety data sheet (SDS) [3] and the UN38.3 transport test report [4]. Each row names its source or shows its formula.
| SPECIFICATION | VALUE | CONDITION · SOURCE |
|---|---|---|
| RATED · MANUFACTURER copied from data sheet [1] and specification [2] | ||
| MODEL CODE | INR-18650-P28A | as printed [1][2]; designation INR19/66 [2] |
| CAPACITY, TYPICAL | 2,800 mAh | 10.3 Wh [1]; rated discharge 0.56 A to 2.5 V after rated charge, 23 °C [2] |
| CAPACITY, MINIMUM | 2,700 mAh | 9.56 Wh [1]; same rated discharge [2] |
| NOMINAL VOLTAGE | 3.6 V | mean voltage during rated discharge [1][2] |
| CHARGE VOLTAGE | 4.20 V | ± 0.05 V, end of charge, CC-CV [2]; 4.2 V [1] |
| DISCHARGE CUT-OFF | 2.5 V | [1][2] |
| STANDARD CHARGE | 2.8 A | CC-CV to 4.2 V for 1.5 h or 50 mA, 23 °C; 90 min [1][2] |
| MAXIMUM CHARGE | 8.4 A | “See Section 4.14” [2]: 23–45 °C only, in [2]’s “safe operating region”; 5.6 A in its specified region (fig 5.6); no condition printed in [1] |
| MAXIMUM DISCHARGE | 35 A | “with 80 oC temp. cut”; “Cycle life is reduced at high rates” [2]; no condition printed in [1]; neither document says continuous |
| CHARGE TEMPERATURE | 0 to 60 °C | ambient [1]; see the charge-current limits by temperature [2] |
| DISCHARGE TEMPERATURE | −40 to 60 °C | ambient [1]; “reduced discharge voltage” from −20 to −40 °C [2] |
| CELL SURFACE, MAXIMUM | 80 °C | “must not exceed 80°C” [2] |
| AC IMPEDANCE | ≤ 20 mΩ | fresh cell, AC 1 kHz; state of charge not stated [1][2] |
| DC RESISTANCE | 20 mΩ | 10 A for 1 s; no maximum or typical stated [1] |
| ENERGY DENSITY | 589 · 219 | Wh/l · Wh/kg [1] |
| SHIPPING VOLTAGE | ≥ 3.45 V | about 30 % charge or less [2] |
| STORAGE | < 23 °C | long term; below 35 °C when shipped; shelf life 1 year [2] |
| DIAMETER | 18.30 mm | ± 0.30 mm [2]; 18.6 mm maximum [1] |
| HEIGHT | 65.05 mm | ± 0.15 mm [2]; 65.2 mm maximum [1] |
| MASS | 48.0 g | maximum [2]; 46 g typical [1] |
| SHAPE · CAN | Cylindrical · steel | [1] |
| TERMINAL · PROTECTION | Flat top · none | as sold: bare cell, no protection circuit; terminal style not stated [1][2] |
| MINIMUMS · SPECIFICATION electrical performance and cycle life, as printed [2] | ||
| MINIMUM AT 0.56 A | 2,700 mAh | to 2.5 V after rated charge, 23 °C; printed 2.70 Ah [2] |
| MINIMUM AT 2.8 A | 2,600 mAh | to 2.5 V after rated charge, 23 °C; printed 2.60 Ah [2] |
| MINIMUM AT 10 A | 2,550 mAh | to 2.5 V after rated charge, 23 °C; printed 2.55 Ah [2] |
| MINIMUM AT 15 A | 2,500 mAh | to 2.5 V after rated charge, 23 °C; printed 2.50 Ah [2] |
| MINIMUM AT 20 A | 2,500 mAh | to 2.5 V after rated charge, 23 °C; printed 2.50 Ah [2] |
| MINIMUM AT 45 °C | 2,600 mAh | 2.8 A to 2.5 V, charged at 23 °C [2] |
| MINIMUM AT 0 °C | 2,100 mAh | 2.8 A to 2.5 V, charged at 23 °C [2] |
| MINIMUM AT −20 °C | 2,000 mAh | 2.8 A to 2.5 V, charged at 23 °C [2] |
| CYCLE LIFE | ≥ 80 % | after 500 cycles at 10 A, 23 °C; % = Ah ÷ 2.55 Ah, the 10 A minimum [2] |
| + Source: [1] Molicel, Product Data Sheet, Model INR-18650-P28A, Version 1.3 (as printed; no date printed); on file 2026-10-20 · Data sheet PDF + Source: [2] E-One Moli Energy Corp., Cell Specifications of INR18650-P28A, Doc. INR18650P28A-01, Ver. 1.2, 2024/05/21 (as printed); on file 2024-10-04; not posted, as Molicel marks it confidential. Questions about its figures: call or text us | ||
| SPECIFICATION | VALUE | CONDITION · SOURCE |
|---|---|---|
| READ FROM DATA-SHEET CHARTS digitized from the vector charts in [1], about ±0.5 % of each axis | ||
| CAPACITY AT 10 A | 2,728 mAh | CC to 2.5 V, 23 °C [1] |
| CAPACITY AT 30 A | 2,728 mAh | CC to 2.5 V, 23 °C [1] |
| CAPACITY AT −20 °C | 2,466 mAh | 2.8 A to 2.5 V; 90 % of the 23 °C curve [1] |
| 5.6 A CHARGE, TO FULL | 53 min | CC-CV to 4.2 V, 50 mA, 23 °C; 2.8 A takes 79 min [1] |
| RETENTION, 500 CYCLES · 10 A | 84 % | 2.8 A charge, 10 A discharge, 23 °C; % basis not printed [1] |
| RETENTION, 500 CYCLES · 20 A | 80 % | 2.8 A charge, 20 A discharge, 23 °C; % basis not printed [1] |
| CALCULATED arithmetic on [1] and [2], shown so you can check it | ||
| 1C | 2.8 A | the current that delivers the typical capacity in one hour: 2,800 mAh [1] ÷ 1 h |
| MAXIMUM DISCHARGE AS C-RATE | 12.5C | 35 A maximum, with an 80 °C cut-off [2], ÷ 2.8 A; not a continuous rating |
| MAXIMUM CHARGE AS C-RATE | 3C | 8.4 A [1][2] ÷ 2.8 A: 23–45 °C only, [2]’s “safe operating region”; 2C (5.6 A) in its specified region |
| ENERGY AT 30 A | 8.68 Wh | ∫V dQ along the 30 A curve to 2.5 V [1] |
| AVERAGE POWER AT 30 A | 95 W | 30 A × 3.18 V average of that curve [1] |
| FROM THE SAFETY DATA SHEET (SDS) AND UN38.3 TRANSPORT TEST REPORT copied as printed from [3] and [4] | ||
| CHEMISTRY | Li-ion | [1][2] say lithium-ion only; the SDS lists cathode metals for all Molicel cells, not per model [3] |
| ENERGY · SDS | 10.08 Wh | Wh rating, 3.60 V × 2.80 Ah; 9.72 Wh minimum [3] |
| LITHIUM CONTENT | 0.84 g | equivalent lithium content [3] |
| MASS · SDS | 48.0 g | as printed, basis not stated [3] |
| MASS · UN38.3 TEST CELLS | 45.283–45.525 g | the 10 cells AnTek weighed before T1 [4]; not our lot |
| TRANSPORT | UN3480 · Class 9 | UN3481 when packed with or contained in equipment [3] |
| UN38.3 | TW1906117-001 | T1–T6 and T8 passed (T8 at 35 A); T7 not applicable to cells; AnTek Certification, 2019-07-12 [4] |
| SAFETY DATA SHEET | FSSF00058BJ | version field prints BI, issued 2025-01-10; lists INR18650-P28A by name [3] |
| + Source: [1] Molicel, Product Data Sheet, Model INR-18650-P28A, Version 1.3 (as printed; no date printed); on file 2026-10-20 · Data sheet PDF + Source: [2] E-One Moli Energy Corp., Cell Specifications of INR18650-P28A, Doc. INR18650P28A-01, Ver. 1.2, 2024/05/21 (as printed); on file 2024-10-04; not posted, as Molicel marks it confidential. Questions about its figures: call or text us + Source: [3] Molicel, Safety Data Sheet FSSF00058BJ, Molicel Rechargeable Lithium-ion cells and multi-cell battery packs; version field prints BI, the revision history’s latest entry is BJ; issued 2025-01-10; on file 2026-10-20 · SDS PDF + Source: [4] AnTek Certification Inc., Lithium Ion Battery Safety Testing Report, INR-18650-P28A, report TW1906117-001, issued 2019-07-12, to UN Manual of Tests and Criteria Rev. 6, Amend. 1; on file 2026-10-20 · UN38.3 report PDF | ||
Black marks: rated voltages [1][2]. Orange band: where the middle 80 % of capacity is delivered at 0.56 A, 3.21–4.05 V, read from the 0.56 A curve digitized from [1].
Currents as rated, each with its condition [1][2]. C-rates calculated against 2,800 mAh typical. Charge limits by temperature are in fig 5.6. The 35 A figure is printed as a maximum with an 80 °C cut-off, not as a continuous rating; no pulse rating is printed.
Operating ranges as rated, in °C [1][2]. [2] adds that the cell surface must not exceed 80 °C, the same 80 °C as the cut-off on the 35 A maximum discharge. Last row: the test temperatures of the data sheet’s discharge-temperature chart, shown in section 04 below.
Each document’s capacity figure, as printed, on a 2,500–2,900 mAh scale; the axis doesn’t start at zero. The 2019 version of the data sheet printed a 2,600 mAh minimum; Version 1.3 [1] and the 2024 specification [2] print 2,700 mAh.
Energy figures in Wh on a 9.0–11.0 Wh scale. The SDS rating is nominal voltage × capacity, 3.60 V × 2.80 Ah [3]; the data sheet’s 10.3 Wh is higher and its basis isn’t printed [1]. Our integration of the 0.56 A curve is the last row. Shipping paperwork follows the SDS.
Mass figures in grams on a 44–50 g scale. Bar: the range of the 10 cells AnTek weighed before UN38.3 test T1 in 2019 [4], a lab sample, not our lot.
The data sheet’s lowest and highest discharge currents, digitized. At 0.56 A the cell runs to 2.5 V and delivers about 2,849 mAh. At 30 A it delivers about 2,728 mAh, with the voltage 0.49 V lower after 1,500 mAh delivered.
Data: digitized from [1] Discharge Rate Characteristics · 0.56 A and 30 A · charge CC-CV 2.8 A / 4.2 V (50 mA) · discharge CC to 2.5 V · 23 °C · data tables under figs 3.1 and 3.2
03BY CURRENT
Five discharge currents from the data sheet, from 0.56 A to 30 A, beside the minimums the specification sets at five currents. The first two figures are the curves; the rest are arithmetic on them, with the formula under each. The data sheet charts no cell temperature.
Data: digitized from [1] Discharge Rate Characteristics · 0.56 A, 2.8 A, 10 A · charge CC-CV 2.8 A / 4.2 V (50 mA) · discharge CC to 2.5 V · 23 °C
| SERIES | V AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V |
|---|---|---|---|---|---|---|---|---|
| 0.56 A · 0.2C | 4.18 | 3.97 | 3.80 | 3.64 | 3.52 | 3.28 | 2,849 | 2.50 |
| 2.8 A · 1C | 4.14 | 3.90 | 3.73 | 3.58 | 3.45 | 3.20 | 2,734 | 2.49 |
| 10 A · 3.6C | 4.01 | 3.74 | 3.59 | 3.43 | 3.30 | 3.05 | 2,728 | 2.50 |
Data: digitized from [1] Discharge Rate Characteristics · 10 A, 20 A, 30 A · charge CC-CV 2.8 A / 4.2 V (50 mA) · discharge CC to 2.5 V · 23 °C
| SERIES | V AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V |
|---|---|---|---|---|---|---|---|---|
| 10 A · 3.6C | 4.01 | 3.74 | 3.59 | 3.43 | 3.30 | 3.05 | 2,728 | 2.50 |
| 20 A · 7.1C | 3.84 | 3.58 | 3.44 | 3.29 | 3.16 | 2.94 | 2,778 | 2.50 |
| 30 A · 10.7C | 3.67 | 3.43 | 3.30 | 3.16 | 3.04 | 2.82 | 2,728 | 2.50 |
Black: capacity at the end of each curve in [1] Discharge Rate Characteristics, at 2.5 V. Gray: the minimum capacity [2] specifies at that current, to 2.5 V after rated charge at 23 °C. The 20 A curve runs slightly past the 2.8 and 10 A curves, as printed; the data sheet doesn’t say why.
| CURRENT | C-RATE | CURVE END mAh [1] | MINIMUM mAh [2] |
|---|---|---|---|
| 0.56 A | 0.2C | 2,849 | 2,700 |
| 2.8 A | 1C | 2,734 | 2,600 |
| 10 A | 3.6C | 2,728 | 2,550 |
| 15 A | 5.4C | no curve | 2,500 |
| 20 A | 7.1C | 2,778 | 2,500 |
| 30 A | 10.7C | 2,728 | not printed |
Energy = the area under each voltage–capacity curve (∫V dQ), digitized from [1] Discharge Rate Characteristics, to 2.5 V. Data-sheet rating for comparison: 10.3 Wh typical, 9.56 Wh minimum [1].
Cell voltage after the same capacity delivered, read from each curve in [1]. At 1,500 mAh the 30 A curve sits 0.49 V below the 0.56 A curve: 0.49 V ÷ 29.44 A ≈ 17 mΩ (16–18 mΩ across the three depths). Effective resistance = (V at 0.56 A − V at 30 A) ÷ (30 − 0.56) A at the same capacity delivered; arithmetic, not a rating. [1] prints a 20 mΩ DC resistance (10 A for 1 s); self-heating during a long discharge is one possible reason for the difference.
| DEPTH | 0.56 A | 2.8 A | 10 A | 20 A | 30 A | mΩ, 0.56 → 30 A |
|---|---|---|---|---|---|---|
| 500 mAh | 3.97 | 3.90 | 3.74 | 3.58 | 3.43 | 18 |
| 1,500 mAh | 3.64 | 3.58 | 3.43 | 3.29 | 3.16 | 17 |
| 2,300 mAh | 3.42 | 3.35 | 3.19 | 3.07 | 2.95 | 16 |
Power = current × average voltage of each digitized curve in [1], over the whole discharge to 2.5 V; the start of a discharge runs higher, the end lower.
Runtime = capacity delivered ÷ current, from the curves in [1]: from a full CC-CV charge, at 23 °C. A device whose average draw is below its peak current runs longer than the figure at that peak.
Two estimates of heat generated inside one cell, averaged over the discharge. Orange: current × the average voltage gap to the 0.56 A curve, read from [1]. Gray: current² × the 20 mΩ DC resistance (10 A, 1 s) [1]. The data sheet charts no cell temperature. In a pack, neighboring cells add their heat: plan cooling, and derate.
Each point is one digitized curve from [1] Discharge Rate Characteristics: energy delivered against average power, power on a log scale.
| CURRENT | AVERAGE W | ENERGY Wh | RUNTIME |
|---|---|---|---|
| 0.56 A · 0.2C | 2.0 | 10.39 | 5 h 05 min |
| 2.8 A · 1C | 10.1 | 9.86 | 59 min |
| 10 A · 3.6C | 34.6 | 9.44 | 16 min |
| 20 A · 7.1C | 66.1 | 9.18 | 8.3 min |
| 30 A · 10.7C | 95.4 | 8.68 | 5.5 min |
04BY TEMPERATURE
Seven test temperatures from −40 to 60 °C, digitized from the data sheet, all at 2.8 A after a charge at 23 °C. The chart doesn’t say whether these are ambient or cell temperatures. The specification sets minimums at 45, 23, 0 and −20 °C.
Data: digitized from [1] Discharge Temperature Characteristics · charge CC-CV 2.8 A / 4.2 V (50 mA) at 23 °C · discharge 2.8 A to 2.5 V at each temperature · the chart doesn’t say whether these are ambient or cell temperatures
| SERIES | V AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V |
|---|---|---|---|---|---|---|---|---|
| 23 °C | 4.14 | 3.90 | 3.73 | 3.58 | 3.45 | 3.20 | 2,734 | 2.49 |
| 45 °C | 4.18 | 3.92 | 3.76 | 3.61 | 3.47 | 3.23 | 2,846 | 2.49 |
| 60 °C | 4.18 | 3.93 | 3.77 | 3.61 | 3.47 | 3.22 | 2,835 | 2.50 |
Data: digitized from [1] Discharge Temperature Characteristics · charge CC-CV 2.8 A / 4.2 V (50 mA) at 23 °C · discharge 2.8 A to 2.5 V at each temperature · the chart doesn’t say whether these are ambient or cell temperatures
| SERIES | V AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V |
|---|---|---|---|---|---|---|---|---|
| 0 °C | 4.19 | 3.80 | 3.65 | 3.49 | 3.35 | 2.95 | 2,579 | 2.49 |
| −20 °C | 4.18 | 3.64 | 3.50 | 3.32 | 3.16 | trace ended | 2,466 | 2.49 |
| −30 °C | 4.19 | 3.52 | 3.38 | 3.20 | 3.02 | trace ended | 2,396 | 2.49 |
Data: digitized from [1] Discharge Temperature Characteristics · charge CC-CV 2.8 A / 4.2 V (50 mA) at 23 °C · discharge 2.8 A to 2.5 V at each temperature · the chart doesn’t say whether these are ambient or cell temperatures
| SERIES | V AT 0 mAh | 500 | 1,000 | 1,500 | 2,000 | 2,500 | END mAh | END V |
|---|---|---|---|---|---|---|---|---|
| 23 °C | 4.14 | 3.90 | 3.73 | 3.58 | 3.45 | 3.20 | 2,734 | 2.49 |
| −40 °C | 4.19 | 3.31 | 3.16 | 2.97 | 2.73 | trace ended | 2,238 | 2.49 |
Black: end capacity of each temperature curve in [1], 2.8 A to 2.5 V. Gray: the minimum [2] specifies at 45, 0 and −20 °C, and its 2.8 A minimum at 23 °C, all at 2.8 A after a rated charge at 23 °C.
| TEMPERATURE | CURVE END mAh [1] | % OF 23 °C | MINIMUM mAh [2] |
|---|---|---|---|
| 60 °C | 2,835 | 104 | not printed |
| 45 °C | 2,846 | 104 | 2,600 |
| 23 °C | 2,734 | 100 | 2,600 |
| 0 °C | 2,579 | 94 | 2,100 |
| −20 °C | 2,466 | 90 | 2,000 |
| −30 °C | 2,396 | 88 | not printed |
| −40 °C | 2,238 | 82 | not printed |
Average voltage = energy ÷ capacity for each digitized temperature curve in [1], at 2.8 A. The line joins the seven curves. Lower voltage at the same current means less power and more heat; [2] notes “reduced discharge voltage” from −20 to −40 °C.
| TEMPERATURE | CAPACITY mAh | % OF 23 °C | ENERGY Wh | AVERAGE V |
|---|---|---|---|---|
| 60 °C | 2,835 | 104 | 10.24 | 3.61 |
| 45 °C | 2,846 | 104 | 10.27 | 3.61 |
| 23 °C | 2,734 | 100 | 9.86 | 3.61 |
| 0 °C | 2,579 | 94 | 9.12 | 3.54 |
| −20 °C | 2,466 | 90 | 8.32 | 3.38 |
| −30 °C | 2,396 | 88 | 7.80 | 3.26 |
| −40 °C | 2,238 | 82 | 6.81 | 3.04 |
05CHARGING
The data sheet charts a 2.8 A standard charge and a 5.6 A charge, both CC-CV to 4.2 V at 23 °C [1]. Figs 5.1 to 5.3 are its traces; figs 5.4 and 5.5 add up the charge each test put in; fig 5.6 is the specification’s limit on charge current by temperature, [2] §4.14.
Data: digitized from [1] Charge Characteristics · 2.8 A (1C) and 5.6 A (2C) · CC-CV to 4.2 V, 50 mA cut, at 23 °C
| CHARGE | 0 min | 10 min | 20 min | 30 min | 45 min | 60 min | 75 min |
|---|---|---|---|---|---|---|---|
| 2.8 A · 1C | 3.14 V | 3.57 V | 3.69 V | 3.81 V | 4.04 V | 4.20 V | 4.20 V |
| 5.6 A · 2C | 3.06 V | 3.74 V | 4.00 V | 4.20 V | 4.20 V | trace ended | trace ended |
Data: digitized from [1] Charge Characteristics · 2.8 A (1C) and 5.6 A (2C) · CC-CV to 4.2 V, 50 mA cut, at 23 °C
| CHARGE | 0 min | 10 min | 20 min | 30 min | 45 min | 60 min | 75 min |
|---|---|---|---|---|---|---|---|
| 2.8 A · 1C | 2.8 A | 2.8 A | 2.8 A | 2.8 A | 2.8 A | 0.8 A | 0.1 A |
| 5.6 A · 2C | 5.6 A | 5.6 A | 5.6 A | 3.5 A | 0.2 A | trace ended | trace ended |
Data: digitized from [1] Charge Characteristics · 2.8 A (1C) and 5.6 A (2C) · CC-CV to 4.2 V, 50 mA cut, at 23 °C · each curve is a percent of its own test’s total: about 2,741 mAh at 2.8 A, and about 2,775 mAh implied at 5.6 A (fig 5.4)
| CHARGE | 0 min | 10 min | 20 min | 30 min | 45 min | 60 min | 75 min |
|---|---|---|---|---|---|---|---|
| 2.8 A · 1C | 0 % | 17 % | 34 % | 51 % | 77 % | 97 % | 100 % |
| 5.6 A · 2C | 0 % | 34 % | 67 % | 94 % | 100 % | trace ended | trace ended |
Charge put in = current × time, summed along each current trace digitized from [1]. The 2.8 A test puts in about 2,741 mAh in all, the same as its percent curve implies. At 5.6 A the line stops at the end of the constant-current stage, 2,307 mAh after 25 min: summing the current taper drawn after that gives about 2,994 mAh, more than the percent curve implies (about 2,775 mAh) and more than the 0.56 A discharge delivers, so the taper in [1] appears drawn schematically. Dotted line: 2,800 mAh typical [1].
| CHARGE | 5 min | 10 min | 15 min | 20 min | 30 min | 45 min | 60 min | TOTAL mAh |
|---|---|---|---|---|---|---|---|---|
| 2.8 A · 1C | 233 | 467 | 700 | 933 | 1,400 | 2,100 | 2,665 | 2,741 |
| 5.6 A · 2C | 467 | 934 | 1,400 | 1,867 | after CC stage | after CC stage | after CC stage | ≈2,775, from the % curve |
Minutes to put in each amount, from the current traces digitized from [1] (current × time). Constant-current stage: about 25 min and 2,307 mAh at 5.6 A; about 54 min and 2,502 mAh at 2.8 A. Standard charge time per the data sheet: 1.5 h at 2.8 A [1].
| CHARGE | 1,000 mAh | 1,500 mAh | 2,000 mAh | 2,240 mAh | CC STAGE ENDS | PUT IN AT CC END | TOTAL PUT IN |
|---|---|---|---|---|---|---|---|
| 2.8 A · 1C | 21 min | 32 min | 43 min | 48 min | 54 min | 2,502 mAh | 2,741 mAh |
| 5.6 A · 2C | 11 min | 16 min | 21 min | 24 min | 25 min | 2,307 mAh | ≈2,775 mAh, from the % curve |
Data: digitized from the chart in [2] §4.14, “Charge Rate vs Temperature”, charge voltage 4.2 V. Gray: [2]’s “safe operating region” (dashed in [2]). Orange: its “specified operating region” (solid in [2]). 8.4 A appears only on the gray line, from 23 to 45 °C; the orange line tops out at 5.6 A there. The gray line runs to 70 °C, past the 0–60 °C charge range both documents print [1][2]. [2] doesn’t say whether these are ambient or cell temperatures.
| REGION, AS PRINTED | MAXIMUM CHARGE CURRENT BY TEMPERATURE |
|---|---|
| Specified operating region | 0–10 °C: 1.4 A; 10–23 °C: 2.8 A; 23–45 °C: 5.6 A; 45–60 °C: 2.8 A |
| Safe operating region | 0–23 °C: 2.8 A; 23–45 °C: 8.4 A; 45–60 °C: 5.6 A; 60–70 °C: 2.8 A |
06CYCLE LIFE AND STORAGE
Two test programs from the data sheet at 23 °C, 2.8 A charge with 10 or 20 A discharge [1], and the specification’s cycle-life rating: at least 80 % after 500 cycles at 10 A [2]. Then how much charge a stored cell keeps [2].
Data: digitized from [1] Cycle Characteristics, one marker per cycle, joined here · charge CC-CV 2.8 A / 4.2 V (50 mA) · discharge 10 A or 20 A to 2.5 V, rest 10 or 30 min · 23 °C · [1] doesn’t print what 100 % is; cycle 1 reads 100 % · axis starts at 60 % · dotted line: the ≥ 80 % clause in [2], whose percent is Ah ÷ 2.55 Ah, the 10 A minimum
| TEST | 100 | 200 | 300 | 400 | 500 CYCLES |
|---|---|---|---|---|---|
| 10A discharge | 90.8 % | 88.3 % | 86.7 % | 85.4 % | 84.2 % |
| 20A discharge | 87.4 % | 84.3 % | 82.2 % | 80.3 % | 79.5 % |
Capacity at cycle 500, read from the chart in [1] (about ±0.5 points), beside the cycle-life rating in [2]. The chart doesn’t print its 100 % basis and [2] uses 2.55 Ah, so the two are not on one scale. A chart reading and a rating, not a warranty.
Capacity still in the cell after storage at 23 °C from 30 % charge, as rated in [2]: the first discharge after storage, as a percent of 2.70 Ah. A cell stored at 30 % starts at about 30 %, so these show how much charge it keeps, not lasting loss. [2] asks for storage below 23 °C, above 2.5 V, recharged to 30 % if the voltage nears 2.5 V.
07TRANSPORT TESTS
AnTek Certification’s 2019 UN38.3 report [4] records “Passed” for T1–T6 and T8 on the INR-18650-P28A; T7, overcharge, doesn’t apply to cells. AnTek is a test lab, separate from Molicel. Its tables also print what each cell did: a 2019 lab sample, not our lot.
Highest external temperature each cell reached, as printed in [4]: one tick per cell, the bar spans the lowest to the highest. T5: case heated to 57 ± 4 °C, then shorted through 75–84 mΩ. T6: a 9.1 kg mass dropped onto a bar across the cell. T8 forced discharge ran 20 cells at 35 A for 0.08 h; [4] prints no temperatures for it. Every result is “Passed” in [4], a 2019 lab sample, not our lot.
| TEST | CELLS | MAX °C, EACH CELL | RANGE |
|---|---|---|---|
| T5 external short | 10 | 103.5, 99.5, 99, 104.7, 102.7, 104.1, 96.6, 105.7, 107.3, 104.6 | 96.6–107.3 |
| T6 impact | 10 | 28.4, 27, 28.8, 27.9, 27.1, 28.6, 29.1, 27.5, 28.9, 28.4 | 27–29.1 |
Open-circuit voltage after each test, as a percent of the voltage just before it, printed for each of the 10 cells in [4]: one tick per cell. The cells started at 4.198–4.213 V, fully charged. The scale starts at 85 %.
Mass of the 10 cells AnTek weighed before T1, as printed in [4]: 45.283–45.525 g (mean 45.40 g, our arithmetic), against 48.0 g maximum [2] and 46 g typical [1]. Mass loss after each of T1–T4: 0.00–0.01 % [4]. The axis starts at 44.5 g.
| CELL | STATE | BEFORE T1 g |
|---|---|---|
| 01 | first cycle | 45.513 |
| 02 | first cycle | 45.456 |
| 03 | first cycle | 45.496 |
| 04 | first cycle | 45.525 |
| 05 | first cycle | 45.372 |
| 06 | after 25 cycles | 45.283 |
| 07 | after 25 cycles | 45.401 |
| 08 | after 25 cycles | 45.302 |
| 09 | after 25 cycles | 45.303 |
| 10 | after 25 cycles | 45.309 |
| TEST | METHOD, CONDENSED FROM [2] | CRITERIA | SECTION |
|---|---|---|---|
| Heating | at 100% SOC, oven raised 5 °C (± 2 °C) per minute to 130 °C (± 2 °C), held 10 minutes | No fire or explosion | [2] §5.5.1 |
| Short circuit | in a preheated oven at 57 ± 4°C cell temperature, external resistance < 0.1 ohm (UN method) | No disassembly, rupture or fire within 6 hours of test. Max temp: < 150°C. | [2] §5.5.2 |
| Overcharge | charging at 25.2A to 15V from the fully discharged state for 2.5hrs | No fire or explosion | [2] §5.5.2 |
| Forced discharge | in series with a 12V DC supply at a current equal to the maximum discharge specified (UN method) | No disassembly and no fire within 7 days of test | [2] §5.5.2 |
| Crush | between two flat plates, applied force about 13KN | No fire or explosion | [2] §5.5.3 |
| Impact | 15.8mmφ bar with 9.1kg weight dropped from 61cm | No fire or explosion | [2] §5.5.3 |
| Drop | 3ft onto concrete, 3 times each for bottom, side and header (9 drops) | No visible electrolyte leakage, no temperature rising. | [2] §5.6 |
| High temperature storage | 0.56A discharge capacity test after 10h at 85°C | No leakage, no vent, no fire or explosion | [2] §5.6 |
Methods condensed from [2] §5.5 and §5.6; criteria as printed. Not shown: its thermal, shock, vibration and altitude tests (UN methods; see the UN38.3 results above). [2] lists these as tests the cell is specified to meet and prints no results. The UN38.3 results above are a different set of tests, from [4].
08COMPARE
Nine other 18650 cells, each from its own data sheet. A higher discharge rating usually costs capacity. The conditions behind each rating differ, so the table quotes each sheet’s wording.
Bars show each printed figure, not like-for-like ratings: the P28A’s 35 A is a maximum with an 80 °C cut-off [2], while the P30B, 30Q and VTC6 figures are continuous ratings [5]. The P28A row comes from its specification [2] (the data sheet prints no condition [1]); the others are copied from their own data sheets [5]. Bars start at zero: minimum capacity on a 0–3,500 mAh scale, discharge on 0–40 A. Pulse and other non-continuous figures are left out.
| CELL | TYPICAL OR NOMINAL mAh | MINIMUM mAh | DISCHARGE RATING AS PRINTED | CHARGE RATING AS PRINTED | MASS g |
|---|---|---|---|---|---|
| Molicel P28B INR-18650-P28B |
2,800 typical | 2,650 | “Discharge Current, Continuous: 40 A (80°C cut-off)” | “8.4 A (70°C cut-off)” | 48 max |
| Molicel P28A INR-18650-P28A |
2,800 typical | 2,700 | “Maximum discharging current 35A (with 80 oC temp. cut)” [2]; the data sheet prints “Discharge Current Maximum 35 A” [1] | “8.4A”, “See Section 4.14” [2] | 48 max |
|
Molicel P26A INR-18650-P26A |
2,600 typical | 2,500 | “Maximum discharging current: 35A” (no condition printed) | “6A” | 48 max |
|
Sony/Murata VTC6 US18650VTC6 |
3,120 nominal | 3,000 | “Continuous Maximum Discharge Current: 30A (With 80 deg temperature cut)” / “15A (Without 80 deg temperature cut)” | “Continuous Maximum Charge Current: 5.0A” | 46.6 typical |
|
Samsung 30Q INR18650-30Q6 |
3,000 nominal | 2,950 | “Max. continuous discharge: 15A (Without temperature cut) / 30A (With 80℃ temperature cut)” | “Rated charge: CCCV, 4A, 4.20V, 100mA cut-off” | 48 max |
|
Molicel P30B INR-18650-P30B |
3,000 typical | 2,900 | “Discharge Current, Continuous: 30 A (80°C cut-off)” | “9 A (60°C cut-off)” | 47 max |
|
Samsung 25R INR18650-25R |
not printed | 2,500 | “Max. continuous discharge: 20A (@ RT)” | “Rated charge: CCCV, 4A, 4.20V, 100mA cut-off” | 45 max |
| LG HG2 18650HG2 |
3,000 nominal | Not stated by manufacturer | “Max. Discharge Current, For continuous discharge: 20000mA” | “Max. Charge Current: 4000mA” | 48 max |
|
Molicel M35A INR-18650-M35A |
3,450 typical | 3,350 | “Maximum discharging current: 10 A” (no condition printed) | “1.7 A, see Section 4.14” | 48 max |
|
Samsung 35E INR18650-35E |
not printed | 3,350 | “Max. Discharge Current: 8,000mA (for continuous discharge)” (non-continuous figure not shown) | “2,000mA (not for cycle life)” | 50 max |
Text in quotation marks is copied as printed from each manufacturer document, the specification [2] for the P28A and data sheets [5] for the others, newest version in our library, checked by a second reading; notes in parentheses are ours. Links go to the bare-cell listing in our store.
09PACK MATH
How the single-cell ratings scale in series (S) and parallel (P). Illustrative arithmetic, not a pack rating.
charge voltage [1][2]
nominal voltage [1][2]
Ah minimum; 2.8 × P typical [1][2]
A: the 35 A single-cell maximum, 80 °C cut-off [2], times P*
| CONFIG | CELLS | V MAX | V NOMINAL | Ah MINIMUM | Wh MINIMUM | MAXIMUM A, 80 °C CUT-OFF* | CELL MASS g, MAX |
|---|---|---|---|---|---|---|---|
| 1S1P | 1 | 4.2 | 3.6 | 2.7 | 9.6 | 35 | 48 |
| 2S1P | 2 | 8.4 | 7.2 | 2.7 | 19.1 | 35 | 96 |
| 3S1P | 3 | 12.6 | 10.8 | 2.7 | 28.7 | 35 | 144 |
| 4S1P | 4 | 16.8 | 14.4 | 2.7 | 38.2 | 35 | 192 |
| 5S2P | 10 | 21.0 | 18.0 | 5.4 | 95.6 | 70 | 480 |
| 6S1P | 6 | 25.2 | 21.6 | 2.7 | 57.4 | 35 | 288 |
| 7S3P | 21 | 29.4 | 25.2 | 8.1 | 200.8 | 105 | 1,008 |
| 10S3P | 30 | 42.0 | 36.0 | 8.1 | 286.8 | 105 | 1,440 |
| 10S4P | 40 | 42.0 | 36.0 | 10.8 | 382.4 | 140 | 1,920 |
| 13S4P | 52 | 54.6 | 46.8 | 10.8 | 497.1 | 140 | 2,496 |
| 14S5P | 70 | 58.8 | 50.4 | 13.5 | 669.2 | 175 | 3,360 |
35 A × P: the single-cell maximum discharging current, with its 80 °C cut-off [2], times the parallel count. A ceiling before derating, not a pack rating.
* 35 A × P multiplies the single-cell maximum (35 A with an 80 °C cut-off [2]; neither document calls it continuous) by the number of cells in parallel. Wh = 9.56 Wh minimum [1] × S × P. [2] notes that cycle life is reduced at high rates and asks a pack to protect each cell: overcharge below 4.3 V, over-discharge at 2.5 V, and over-temperature. Derate, size the BMS, fusing and interconnects for the derated current, and use matched cells of one model and lot. Mass counts cells only. The UN38.3 report [4] covers the bare cell; a pack you build needs its own UN38.3 testing before it ships as UN3480.
10SIZE AND FIT
Drawn at the data sheet’s maximum beside nominal outlines of three common formats. The specification prints 18.30 ± 0.30 by 65.05 ± 0.15 mm; its upper limits match the data sheet’s maximums.
All outlines drawn to the same scale. The P28A at its maximum dimensions [1]; the other outlines are nominal format sizes, for scale only.
| DIMENSION | VALUE | CONDITION |
|---|---|---|
| Diameter | 18.6 mm | maximum [1]; 18.30 ± 0.30 mm [2] |
| Height | 65.2 mm | maximum [1]; 65.05 ± 0.15 mm [2] |
| Mass | 48.0 g | maximum [2]; 46 g typical [1]; 45.283–45.525 g for the 10 cells weighed in [4] |
| Terminal | Flat top | as sold, bare cell |
| Volume | 17.7 cm³ | π × (18.6 ÷ 2)² × 65.2 mm³, the maximum envelope |
Check that your holder or device takes a flat-top cell 65.2 mm long (maximum) [1]. Spot-weld nickel strip for packs; don’t solder to the cell.
11USE IT RIGHT
What this cell is, and how to use it within its ratings.
Questions? Call 1-800-547-3050 or text 1-833-419-2192 to ask a person.
Each posted document is linked as published by its author; versions are listed as printed. The cell specification [2] is on file but not posted: Molicel marks it confidential.
Ships from Stockbridge, GA. Most in-stock orders ship within 1 business day.
12QUESTIONS
Short answers. Where an answer comes from a document, it carries its source; the rest is standard handling practice. Anything else: call 1-800-547-3050 or text 1-833-419-2192.
No. It is a bare flat-top cell with no protection circuit. Use it only in packs with a battery management system (BMS) or in devices built for unprotected cells.
Molicel doesn’t call it one. Its specification gives 35 A as the “maximum discharging current”, with the condition “with 80 oC temp. cut”: the discharge has to stop at 80 °C [2]. [2] doesn’t say where that 80 °C is measured, but it also says the cell surface must not exceed 80 °C, so measure at the cell. The data sheet prints 35 A maximum with no condition [1]. Neither document prints a rating for use without the cut-off, or a pulse rating; [2] warns that peaks above the maximum discharge current may reduce capacity, and that cycle life is reduced at high rates. The cell has no protection circuit, so the cut-off has to come from your pack’s BMS, with a sensor on the hottest cell, or from your device. If you can’t confirm a cut-off, don’t plan on 35 A. The data sheet’s highest discharge curve is 30 A (fig 3.2), and it cycles the cell at 10 and 20 A (fig 6.1) [1].
Those figures are from the 2019 version of the data sheet, which printed a 6.0 A maximum charge and a 2,600 mAh minimum. Version 1.3 [1] and the 2024 specification [2] print 8.4 A (23 to 45 °C only, fig 5.6) and 2,700 mAh. No document we hold prints a pulse rating.
Only from 23 to 45 °C, and only inside what Molicel’s specification calls its “safe operating region” (fig 5.6) [2]. Its narrower “specified operating region” allows 5.6 A from 23 to 45 °C, 2.8 A from 10 to 23 °C and from 45 to 60 °C, and 1.4 A from 0 to 10 °C [2]. The data sheet prints 8.4 A maximum with no condition [1]. The standard charge is 2.8 A, about 90 min [1][2]; above that, use a charger or BMS that reads cell temperature.
A lithium-ion charger with a CC-CV profile (constant current, then constant voltage) that stops at 4.2 V. Not a NiMH, LiFePO4 or lead-acid charger.
Runtime ≈ capacity ÷ current. From the data-sheet curves, from full at 23 °C: about 59 min at 2.8 A, 16 min at 10 A, 8.3 min at 20 A and 5.5 min at 30 A (fig 3.7) [1]. For your own draw, divide 2,500 mAh, the lowest minimum the specification sets (at 15 and 20 A) [2], by your current in mA to get hours: at 5 A, 2,500 ÷ 5,000 = 0.5 h, about 30 min.
In the data sheet’s temperature chart, after a charge at 23 °C and at 2.8 A, the cell delivered 94 % of its 23 °C capacity at 0 °C, 90 % at −20 °C and 82 % at −40 °C [1]. The chart doesn’t say whether those are air or cell temperatures. The specification’s minimums are lower: 2,100 mAh at 0 °C and 2,000 mAh at −20 °C [2]. Voltage also drops in the cold (fig 4.5), so a device may cut off early. Don’t charge below 0 °C.
The specification rates at least 80 % after 500 cycles of 2.8 A charge and 10 A discharge at 23 °C, where 100 % is 2.55 Ah: at least 2,040 mAh at cycle 500 (80 % × 2.55 Ah) [2]. The data sheet’s chart reads about 84 % at cycle 500 with 10 A discharge and about 80 % with 20 A, against a 100 % it doesn’t define (fig 6.1) [1]. Neither document gives an end-of-life cycle count. Heat, current, depth of discharge and storage all change the result.
No. Molicel prohibits its use in e-cigarettes, vaporizers and similar devices [1][2]. It is a component for protected packs and devices built for it.
Don’t solder directly to the cell: the heat can damage the seal and internal parts. Spot-weld nickel strip, or use a holder.
No, not in the same pack. Use cells of the same model and lot, at the same state of charge. In series, the weakest cell reaches 2.5 V first and limits the whole pack, and mismatched cells drift further apart with every cycle.
In a case, away from metal objects, somewhere dry. The specification asks for long-term storage below 23 °C, with the voltage above 2.5 V; if it nears 2.5 V, recharge to about 30 % [2]. The SDS suggests room temperature, 25 ± 5 °C [3]. Check the voltage every few months.
As UN3480, lithium-ion batteries, Class 9, under the SDS [3]; the UN38.3 report [4] covers the bare cell. A pack built from these cells needs its own UN38.3 testing.
13SOURCES
Where every number on this page comes from.