KEY SPECS · TENPOWER INR21700-50XG

SOURCE [1]
SIZE
Ø21.50 × 70.50 mm
max.
CAPACITY
5,000 mAh typ.
4,950 mAh min.
0.2C (1000 mA), 2.5 V cut-off
CURRENT
40 A
max. continuous
without temperature cut off
90 A
max. continuous
with 75 °C temperature cut-off
TEMPERATURE
−20 to 60 °C
discharge · ambient
charge 0 to 45 °C · ambient
TENPOWER · 21700 · INR21700-50XG

A 21700 lithium-ion cell: 5,000 mAh “Nominal capacity” and 4,950 mAh “Minimum Capacity”, both from a 0.2C (1,000 mA) discharge to 2.5 V after a 0.5C (2.5 A) charge to 4.2 V [1] §3.1–3.2, and two maximum continuous discharge currents, printed as “40A (without temperature cut off)” and “90A(with 75℃ temperature cut-off)” [1] §3.7. Tenpower’s specification for it, Version No. V0.2, is marked “TENPOWER confidential proprietary”, so this description quotes it rather than linking it. Its safety data sheet (SDS) [2] and UN38.3 test summary [3] print a person’s telephone number and email address, so this description cites them by number and date rather than linking them (section 11). Below: every rating with its condition, the figures Tenpower prints in its tables, and what we calculated from them, so you can check each number.

CAPACITY5,000 mAhnominal; 4,950 mAh minimum; 0.2C (1,000 mA) to 2.5 V [1] §3.1–3.2
CONTINUOUS40 A“(without temperature cut off)”; 90 A only “(with 75℃ temperature cut-off)” [1] §3.7
MAX. CHARGE15 Ano condition printed [1] §3.6; standard charge “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4
ENERGY18 Whprinted in the SDS, no condition [2] Section 1; 3.6 V × 5,000 mAh = 18.0 Wh, our check; [1] prints no Wh
IMPEDANCE, 1 kHz≤ 4 mΩ“Internal Impedance at 1000 Hz”, “(25±3℃,30%SOC)”, at 30 % state of charge (SOC) [1] §3.3
MASS71.0 g“71.0g max” [1] §3.11

The library holds data sheets where the manufacturer publishes one. This description quotes this cell’s specification, SDS and UN38.3 test summary rather than linking them (section 11).

A bare cell: a component for protected packs and devices built for it. Not for vaping. Charge on a lithium-ion (Li-ion) charger that stops at 4.2 V.

01SPEC PLATE

Every rating, with its condition.

Tenpower’s data sheet for this cell is titled “PRODUCT SPECIFICATION” [1]; this page calls it the specification. The only version we hold is Version No. V0.2, with an Effective Date of 2025/08/14; it is marked “TENPOWER confidential proprietary” on every page and is not marked draft. Its ratings come first, copied as printed. Then the capacity figures its tables print, our arithmetic, and what the safety data sheet (SDS) [2] and the UN38.3 test summary [3] add. Each row names its source or shows its formula.

SPEC PLATE · TENPOWER INR21700-50XG · SPECIFICATION V0.2 SOURCE [1]
SPECIFICATION VALUE CONDITION · SOURCE
RATED · MANUFACTURER copied from specification [1]
MODEL CODE INR21700-50XG Model name and Spec. No., as printed on the cover, in §2 and §5.1 and in every page header; no other form or suffix printed [1]; the SDS [2] and the UN38.3 summary [3] print the same
CAPACITY, NOMINAL 5,000 mAh “Nominal capacity”; “Charge: 0.5C(2.5A), 4.2V, 100mA cut-off”, “Discharge: 0.2C(1000mA), 2.5V cut-off”, “*1C = 5000mA”; no temperature printed (§7.2: tests at 25 ± 3 °C unless specified); the word typical is not printed [1] §3.1
CAPACITY, MINIMUM 4,950 mAh “Minimum Capacity”; the same condition lines [1] §3.2. §8.3 prints the same “≥ 4950mAh” as the standard discharge capacity: 0.2C to 2.5 V after a standard charge, at 25 ± 3 °C [1]
1C 5,000 mA “*1C = 5000mA”, the last line of §3.1 and §3.2; §7.3 defines the C-rate [1]
NOMINAL VOLTAGE 3.6 V [1] §3.5; also §5.2; the SDS [2] and the UN38.3 summary [3] print the same
CHARGE VOLTAGE 4.2 V “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4; “Charging voltage must be set 4.2V/cell.” and, allowing for charger tolerance, “lower than 4.25V/cell”, Proper use 1 [1]
DISCHARGE CUT-OFF 2.5 V “Discharge cut-off voltage”: “2.5 V” [1] §3.9; the capacity, rate and cycle clauses print “2.5V”
STANDARD CHARGE 2.5 A “CCCV, 2.5A, 4.2V, 100mA cut-off”; printed “0.5C(2.5A)” in §3.1–3.2; defined at 25 ± 3 °C in §8.1; no charge time printed [1] §3.4
MAX. CHARGING CURRENT 15 A “15A”; no temperature, voltage, cut-off, duration or charge time printed with it; 3.00C in CALCULATED below [1] §3.6
MAX. CONTINUOUS DISCHARGE 40 A “40A (without temperature cut off)” [1] §3.7; 8.00C in CALCULATED below
MAX. CONTINUOUS DISCHARGE, WITH CUT-OFF 90 A “90A(with 75℃ temperature cut-off)” [1] §3.7; 18.00C in CALCULATED below; not printed: whether the 75 °C is a cell-surface or an ambient temperature, or how long 90 A runs before the cut-off acts
CHARGE TEMPERATURE 0 to 45 °C “Charge : 0 to 45℃”, “Operating ambient temperature” [1] §3.13; at the cell surface “Charge : 0 to 60℃”, “(Recommended recharge release < 45℃)” [1] §3.14
DISCHARGE TEMPERATURE −20 to 60 °C “Discharge:-20 to 60℃”, ambient [1] §3.13; at the cell surface “Discharge:-20 to 80℃”, “(Recommended re-discharge release < 60℃)” [1] §3.14
IMPEDANCE, 1 kHz ≤ 4 mΩ “Internal Impedance at 1000 Hz”: “≤4mΩ(25±3℃,30%SOC)”, at 30 % state of charge (SOC) [1] §3.3; §7.1 sets the impedance test at AC 1 kHz; no DC resistance and no typical value printed
CAPACITY AFTER 500 CYCLES ≥ 60 % “Capacity≥60% Initial capacity@500 cycles”; “Charge: 6A, 4.2V, CCCV 100mA cut-off @RT”; “Discharge: 40A, 2.5V or 75℃ cut-off @RT” [1] §3.10; “@RT” is room temperature, and [1] §8.6 runs the test at 25 ± 3 °C
RECOVERY AFTER STORAGE ≥ 90 % 30 days at 60 ± 3 °C after the standard charge; recovery capacity from a 10 A discharge to 2.5 V at 25 °C after a standard charge; the 100 % basis is not printed [1] §8.7
STORAGE TEMPERATURE −20 to 25 °C “1 year: -20~25℃(*)”; “3 month : -20~45℃(*)”; “1 month: -20~60℃(*)”; Note (*): for a cell kept in its ex-factory state, “(below 30% of charge)”, recovery “more than 90% of standard discharge capacity” [1] §3.15
STORAGE HUMIDITY ≤ 60 % “≤60%” [1] §3.16
EX-FACTORY VOLTAGE 3.50–3.59 V open-circuit voltage “within 90days from shipping date”, “(Temperature condition:15~30℃)”; “shipped in 30% charged state”, below 30 % in its Chinese line and Note (*); §8.8 is headed “Status of the cell as of ex-factory”, so the date is the maker’s shipping date [1]
DIAMETER ≤ 21.50 mm “Diameter : ≤21.50mm” [1] §3.12; “Diameter≤21.50mm”, Fig. 1
HEIGHT ≤ 70.50 mm “Height : ≤70.50mm” [1] §3.12; “Height≤70.50mm”, Fig. 1
NO-WELD ZONE Not stated Not stated by manufacturer: [1] prints no prohibited welding area
MASS 71.0 g “71.0g max” [1] §3.11; its history record changes “重量Weight: 75g max” to “重量Weight: 71g max” in Rev. 0.2 (p19)
TERMINAL Not stated Not stated by manufacturer: [1] names no terminal style
+ Source: [1] Tenpower “PRODUCT SPECIFICATION”, Spec. No. INR21700-50XG, Version No. V0.2, Effective Date 2025/08/14 (as printed); marked “TENPOWER confidential proprietary”; on file; quoted in this description, not linked from it (Sources, section 13)
SPEC PLATE · TENPOWER INR21700-50XG · PRINTED TABLES, ARITHMETIC, DOCUMENTS SOURCES [1][2][3]
SPECIFICATION VALUE CONDITION · SOURCE
PRINTED IN THE SPECIFICATION’S TABLES percent as printed; mAh calculated only from the §8.4 index of 4,950 mAh [1]
CAPACITY AT 40 A 93 % ≈ 4,604 mAh, calculated: 93 % × 4,950 mAh, the printed index “(=4950mAh)”; to 2.5 V after standard charge to 4.2 V [1] §8.4
CAPACITY AT 50 A 92 % ≈ 4,554 mAh; a test current above “40A (without temperature cut off)”; the table has no 90 A point [1] §8.4
CAPACITY AT 10 A 94 % ≈ 4,653 mAh; lower than at 20 and 30 A (95 %), as printed [1] §8.4
CAPACITY AT −20 °C, 30 A 90 % of the capacity at 25 °C, for which [1] prints no mAh, so none is calculated; 30 A to 2.5 V after standard charge (its Chinese line: “倍率充电后”, after rate charging) [1] §8.5
CAPACITY AT 60 °C, 30 A 100 % the same as at 25 °C, as printed [1] §8.5
CALCULATED arithmetic on [1], shown so you can check it
40 A AS A C-RATE 8.00C 40 A “(without temperature cut off)” ÷ 5.000 A, the printed “*1C = 5000mA” [1]
90 A AS A C-RATE 18.00C 90 A “(with 75℃ temperature cut-off)” ÷ 5.000 A [1]
15 A AS A C-RATE 3.00C the “Max. charging current” of “15A”, no condition printed, ÷ 5.000 A [1] §3.6
RUNTIME AT 40 A 6.9 min 4,604 mAh ÷ 40,000 mA × 60, from [1] §8.4
ENERGY, CHECK 18.0 Wh 3.6 V nominal voltage × 5,000 mAh nominal capacity [1] §3.5, §3.1; equals the “18 Wh” printed in the SDS [2] Section 1
VOLUME 25.6 cm³ π × (21.50 mm ÷ 2)² × 70.50 mm ≈ 25,595 mm³, at the printed limits; a plain cylinder [1]
DOCUMENTED · WHAT WE HOLD the documents on file for this cell, copied as printed from [1], [2] and [3]
NAME ON THIS PAGE 50XG the name we list the cell under; [1], [2] and [3] print it only within the model name INR21700-50XG
SPECIFICATION V0.2 “PRODUCT SPECIFICATION”, Effective Date 2025/08/14; marked “TENPOWER confidential proprietary” on every page; not marked draft; on file; quoted in this description, not linked from it [1]
OTHER VERSIONS Not on file its history record lists Rev. 0.1, dated “25/5/8”, and one change in Rev. 0.2, dated “25/8/10”: “重量Weight: 75g max” to “重量Weight: 71g max” [1] p19
CHEMISTRY Li-ion “Cell (lithium-ion rechargeable cell)”, no cathode named [1] §2; the SDS lists “lithium nickel cobalt manganess oxides” (镍钴锰酸锂; “manganess” as printed), CAS 182442-95-1, with “35.94%” printed beside it [2] Section 3
ENERGY 18 Wh “3.6V, 5000mAh, 18 Wh” under “Ratings/额定参数”, no condition printed [2] Section 1; [1] and [3] print no Wh
TRANSPORT UN3480 or UN3481 by air, under the “2026 IATA Dangerous Goods regulations 67th Edition”, “Class 9(PI965 Section 1B) or Not applicable (PI966 -967 Section I)”, as printed; its Chinese air line numbers the sections IB and II (第IB部分, 第II部分), and its English packing line prints 965 “Section 1B” and 966-967 “Section Il”, so the class line’s “Section I” for 966–967 disagrees with both (see the shipping question in section 12); by sea “not restricted according to IMOIMDG Code (inc. Amendment 42-24)Special Provision188”, spacing as printed [2] Section 14
SAFETY DATA SHEET 2026TP0350XGSDS Issue Date 2026-01-01; no version or validity printed; compiled by Tenpower; on file; cited in this description, not linked from it [2]
UN38.3 812500500174234 “UN38.3 Test Summary”, issued 2025-09-29, from Shanghai Institute of Chemical Industry Testing Co., Ltd.; T.1–T.6 and T.8 “合格 Passed”, T.7 “/”; on file; cited in this description, not linked from it [3]; section 07 below
SAFETY TESTS Methods only §9 and §10: eight tests, each with a method and a pass criterion; no results, sample counts or test standard printed; section 07 below [1]
+ Source: [1] Tenpower “PRODUCT SPECIFICATION”, Spec. No. INR21700-50XG, Version No. V0.2, Effective Date 2025/08/14 (as printed); marked “TENPOWER confidential proprietary”; on file; quoted in this description, not linked from it (Sources, section 13)
+ Source: [2] HUAIAN TENPOWER LITHIUM CO., LTD., “Safety Data Sheet”, Report No. 2026TP0350XGSDS, Issue Date 2026-01-01 (as printed); no version printed; on file; cited in this description, not linked from it (Sources, section 13)
+ Source: [3] Shanghai Institute of Chemical Industry Testing Co., Ltd., “UN38.3 Test Summary” 812500500174234, issued 2025-09-29 (as printed); no version printed; on file; cited in this description, not linked from it (Sources, section 13)
RATED · [1]FIG 1.1

Voltage window

Black marks: voltages printed in [1] §3.4, §3.5 and §3.9. Orange band: the ex-factory open-circuit voltage “within 90days from shipping date”, 3.50–3.59 V, “(Temperature condition:15~30℃)”, for a cell shipped “in 30% charged state” [1] §8.8 (Tenpower’s shipping date); its Chinese line and Note (*) say below 30 %. [1] sets the charge voltage at 4.2 V and, allowing for charger tolerance, keeps it “lower than 4.25V/cell” (Proper use 1).

RATED · [1]FIG 1.2

Current limits

Standard charge “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4 · 0.5C, printed “0.5C(2.5A)” in §3.1–3.2
2.5 A
Max. charging current “15A”, no condition printed · 3.00C, calculated [1] §3.6
15 A
Max. continuous discharge “40A (without temperature cut off)” · 8.00C, calculated [1] §3.7
40 A
Max. continuous discharge, with cut-off “90A(with 75℃ temperature cut-off)” · 18.00C, calculated [1] §3.7
90 A

Currents as printed in [1], each with its condition; C-rates are our arithmetic on the printed “*1C = 5000mA”. Gray: 90 A, which holds only “(with 75℃ temperature cut-off)”; [1] doesn’t say whether the 75 °C is the cell’s temperature or the air’s. The cycle-life test’s 6 A charge and 40 A discharge ([1] §3.10) are test conditions, not limits. The §3.8 pulse figure is left out: we publish continuous ratings only.

RATED · [1]FIG 1.3

Temperature envelope

Discharge, ambient −20 to 60 °C · “Discharge:-20 to 60℃” [1] §3.13
Discharge, cell surface −20 to 80 °C · re-discharge release “< 60℃” recommended [1] §3.14
Charge, ambient 0 to 45 °C · “Charge : 0 to 45℃” [1] §3.13
Charge, cell surface 0 to 60 °C · recharge release “< 45℃” recommended [1] §3.14
Cut-off printed with the 90 A figure 75 °C · “with 75℃ temperature cut-off”; its basis is not printed [1] §3.7
Printed test points [1] §8.5: −20, −10, 0, 25 and 60 °C

Operating temperatures as printed in [1], on its two bases: “Operating ambient temperature” (§3.13; black, orange for charge) and “Cell surface temperature” (§3.14; gray). Its Chinese lines give the release figures as the recommended temperatures for resuming discharge and charging. The 75 °C mark is the cut-off printed with the 90 A figure. Last row: the temperatures of the capacity table in [1] §8.5, shown in section 04 below.

RATED · [1]FIG 1.4

Storage temperature, by duration

For 1 month −20 to 60 °C · “1 month: -20~60℃(*)”
For 3 months −20 to 45 °C · “3 month : -20~45℃(*)”
For 1 year −20 to 25 °C · “1 year: -20~25℃(*)”

Storage temperature by storage time, as printed in [1] §3.15; orange: the 1-year range. Note (*): “If the cell is kept as ex-factory status (below 30% of charge), the capacity recovery rate is more than 90% of standard discharge capacity.” Its handling section prints the same three ranges, in its own words (section 06 below).

PRINTED + CALC. · [1]FIG 1.5

Printed C-rates, in mA

  • 0.01C activation cut-off [1] §1250 mA0.01 × 5,000
  • 0.1C pre-charge limit, below 2.0 V [1] Proper use 1.2under 500 mA0.1 × 5,000
  • 0.2C capacity discharge [1] §3.1; activation §121,000 mAprinted in §3.1
  • 0.5C standard charge [1] §3.1, §8.12,500 mAprinted in §3.1

[1] prints these four operating and upkeep currents as C-rates, and its current ratings in amps (fig 1.2). mA = C-rate × 5,000 mA, on the printed “*1C = 5000mA”, our arithmetic; “0.2C(1000mA)” and “0.5C(2.5A)” print the current. The pre-charge current is printed “lower than 0.1C”, so it is shown as under 500 mA. Two of its §10 abuse tests are also printed as C-rates: 1C over-discharge and 3C abnormal charging (15,000 mA, our arithmetic). They are test conditions, not ratings; section 07 lists them.

02 · CAPACITY

93 % of 4,950 mAh at 40 A.

Tenpower’s specification prints the capacity at six currents in [1] §8.4, from 0.2C (1,000 mA) to 50 A, each to 2.5 V after a standard charge to 4.2 V, as a percent of “the capacity at 25℃ (=4950mAh)”. At 40 A, the current of its continuous figure “40A (without temperature cut off)” [1] §3.7, it prints 93 %: about 4,604 mAh, which lasts about 6.9 minutes at 40 A by our arithmetic. The table stops at 50 A, 92 %; it has no 90 A point.

0.2C · 1,000 mA4,950 mAh100 %, the printed index “(=4950mAh)” [1] §8.4
40 A4,604 mAh93 % printed in [1] §8.4; mAh = 93 % × 4,950, calculated
CALCULATED FROM [1]FIG 2.1

Data: [1] §8.4, Discharge rate capabilities · constant current to 2.5 V after a standard charge to 4.2 V · percent of “the capacity at 25℃ (=4950mAh)”, mAh calculated · no discharge temperature printed for the points ([1] §7.2: 25 ± 3 °C unless specified) · points only: [1] prints a table, not a curve, so nothing is drawn between them · 50 A is a test current above “40A (without temperature cut off)” [1] §3.7; the table prints no temperature cut-off for any current · y axis starts at 4,450 mAh · data table under fig 3.1

03BY CURRENT

Capacity and runtime, by current.

[1] §8.4 prints the capacity at 0.2C (1,000 mA) and at 10, 20, 30, 40 and 50 A, each to 2.5 V after a standard charge to 4.2 V, as a percent of “the capacity at 25℃ (=4950mAh)”. The mAh, the C-rates and the runtimes are arithmetic on those figures, with the formula under each.

CALCULATED FROM [1]FIG 3.1

Capacity delivered, by current

  • 0.2C 1,000 mA [1] §3.1 · 100 %4,950 mAh
  • 10 A 2.00C · 94 %4,653 mAh
  • 20 A 4.00C · 95 %4,703 mAh
  • 30 A 6.00C · 95 %4,703 mAh
  • 40 A 8.00C · 93 %4,604 mAh
  • 50 A 10.00C · 92 %4,554 mAh

Printed in [1] §8.4 as a percent of “the capacity at 25℃ (=4950mAh)”, each run to 2.5 V after a standard charge to 4.2 V. mAh = percent × 4,950, rounded half up (4,950 mAh is also the §3.2 Minimum Capacity figure); C-rate = current ÷ the printed 1C of 5,000 mA. [1] prints no discharge temperature for these runs (§7.2: 25 ± 3 °C unless specified) and no temperature cut-off for any of them. Orange: 40 A, the current of “40A (without temperature cut off)” [1] §3.7. 50 A is a test current above it; the table has no 90 A point.

DATA TABLE · FIG 3.1
Fig 3.1 data: [1] §8.4 and arithmetic
CURRENT PRINTED % mAh RUNTIME C-RATE
0.2C 100 4,950 4 h 57 min 0.2C, printed
10 A 94 4,653 27.9 min 2.00C
20 A 95 4,703 14.1 min 4.00C
30 A 95 4,703 9.4 min 6.00C
40 A 93 4,604 6.9 min 8.00C
50 A 92 4,554 5.5 min 10.00C
CALCULATED FROM [1]FIG 3.2

Runtime at a constant current

  • 10 A 2.00C · 4,653 mAh27.9 min
  • 20 A 4.00C · 4,703 mAh14.1 min
  • 30 A 6.00C · 4,703 mAh9.4 min
  • 40 A 8.00C · 4,604 mAh6.9 min
  • 50 A 10.00C · 4,554 mAh5.5 min

Runtime = capacity ÷ current, from the mAh in fig 3.1: one standard charge, constant current to 2.5 V. At 0.2C (1,000 mA), 4,950 mAh lasts about 4 h 57 min. A device whose average draw is below its peak current runs longer than the figure at that peak. Orange: 40 A, the current of the continuous figure “40A (without temperature cut off)” [1] §3.7.

40 A or 90 A?

  • 40 A is the continuous maximum printed “40A (without temperature cut off)” under “Max. continuous discharge current” [1] §3.7.
  • 90 A is the continuous maximum printed “90A(with 75℃ temperature cut-off)” [1] §3.7: something has to stop the discharge at 75 °C. In a pack, that is a temperature sensor read by the BMS; in a device, its own temperature cut-off. [1] doesn’t say whether the 75 °C is the cell’s temperature or the air’s, so a sensor on the hottest cell is the cautious choice. Nor does it say how long 90 A can run before the cut-off acts: the cut-off can end a 90 A discharge before the cell is empty. Its cell-surface discharge limit is “Discharge:-20 to 80℃”, with re-discharge release “< 60℃” recommended [1] §3.14.
  • The 500-cycle rating discharges at 40 A to “2.5V or 75℃ cut-off @RT” [1] §3.10: each discharge in that test ends at 2.5 V or at 75 °C, whichever comes first. [1] prints no cycle life at 40 A without the cut-off, or at 90 A.
  • The rate table [1] §8.4 stops at 50 A, 92 % of the 4,950 mAh index; it prints no capacity at 90 A.
  • On the printed 1C of 5,000 mA, 40 A “(without temperature cut off)” is 8.00C and 90 A “(with 75℃ temperature cut-off)” is 18.00C: our arithmetic [1] §3.7.
  • [1] §3.8 also prints a “Pulse discharge current” with a 3-second duration and no rest time, duty cycle, pulse count, state of charge or temperature. We publish continuous ratings only, so we leave it out.
  • If you don’t know whether your pack or device stops the discharge at 75 °C, plan for 40 A.

04TEMPERATURE

Capacity in the cold and the heat.

One table in [1] §8.5: the capacity of a 30 A discharge to 2.5 V at −20, −10, 0, 25 and 60 °C, as a percent of the capacity at 25 °C. At −20 °C, the bottom of the discharge range, it prints 90 %. [1] prints no mAh for that 25 °C capacity, and no charge-temperature table.

PRINTED IN [1]FIG 4.1

Capacity, by discharge temperature

  • −20 °C 30 A to 2.5 V90 %
  • −10 °C 30 A to 2.5 V92 %
  • 0 °C 30 A to 2.5 V95 %
  • 25 °C 30 A to 2.5 V100 %
  • 60 °C 30 A to 2.5 V100 %

A 30 A discharge to 2.5 V at each temperature, printed in [1] §8.5 as a percent of the capacity at 25 °C: “Percentage as an index of the capacity at 25℃is 100%.” Its English line reads “after standard charge”; its Chinese line reads “倍率充电后”, after rate charging, and names no rate. Where charge and discharge temperatures differ, [1] sets a three-hour interval for the temperature change. It prints no mAh for that index, so no mAh is calculated. Orange: −20 °C, the bottom of the ambient discharge range (§3.13).

DATA TABLE · FIG 4.1
Fig 4.1 data: [1] §8.5, as printed
DISCHARGE °C PRINTED % TEST CURRENT
−20 °C 90 30 A
−10 °C 92 30 A
0 °C 95 30 A
25 °C 100 30 A
60 °C 100 30 A

What the table leaves out

  • No mAh. Its index is the capacity at 25 °C, with no mAh printed for it; the rate table’s index is printed “(=4950mAh)”, this one’s isn’t. So this page leaves these figures in percent.
  • One current only: 30 A, 6.00C on the printed 1C (our arithmetic). No table at other currents.
  • No charge-temperature table. [1] allows charging at 0 to 45 °C ambient (§3.13) and 0 to 60 °C at the cell surface (§3.14), and prints no capacity after a cold or hot charge.
  • 60 °C is the top of the ambient discharge range (§3.13); at the cell surface, discharge is allowed to 80 °C (§3.14).

05CHARGING

Charging, as the specification prints it.

The specification prints a 2.5 A standard charge, “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4, and a “Max. charging current” of “15A” with no condition printed [1] §3.6. On the printed 1C of 5,000 mA, 2.5 A is the “0.5C(2.5A)” of §3.1, and 15 A is 3.00C (our arithmetic). Its cycle-life rating charges at 6 A. It prints no charge time. Charge between 0 and 45 °C ambient [1] §3.13.

PRINTED IN [1]FIG 5.1

Voltage thresholds for a pack

Pre-charge below 2.0 V, at “lower than 0.1C”: under 500 mA, 0.1 × 5,000 mA, our arithmetic · Proper use 1.2 [1]
Over-discharge floor “The cell should not be over-discharged below 2.0V.” · Proper use 2.3 [1]
Discharge cut-off 2.5 V [1] §3.9; “Within a voltage range of 2.5V/cell, over-discharge protection should work.” Proper use 5.3 [1]
Charge voltage 4.2 V [1] §3.4; allowing for charger tolerance, “lower than 4.25V/cell”, Proper use 1; “Overcharge protection should work below 4.25V/cell by using.” 5.2 [1]
Working range 2.5 to 4.2 V [1]

Voltage thresholds for a pack’s battery management system (BMS): the cell ratings in [1], and the levels its handling and pack design sections print. Gray: below 2.0 V, where [1] asks for a pre-charge “lower than 0.1C” until the voltage is back above 2.0 V, and says “If the cell voltage unable to reach in specified period/time, stop charging immediately.” [1] prints no time and no lower voltage limit for it. Orange: the working range. The charge-voltage row marks 4.2 V; the 4.25 V limit is quoted in its label.

RATED · [1]FIG 5.2

Charge temperature

Charge, ambient 0 to 45 °C · “Charge : 0 to 45℃”, “Operating ambient temperature” [1] §3.13
Charge, cell surface 0 to 60 °C · “Charge : 0 to 60℃”, “(Recommended recharge release < 45℃)” [1] §3.14
Standard charge “at 25±3℃” · [1] §8.1

Where [1] allows charging, on its two bases: ambient (§3.13; orange, the range this page uses for charging advice) and cell surface (§3.14; gray), with recharging recommended to resume below 45 °C at the cell surface, as its Chinese line words the release figure. [1] prints no capacity after a charge at any other temperature. Below 0 °C, don’t charge.

Before you charge

  • Use a lithium-ion charger with a CC-CV profile (constant current, then constant voltage) that stops at 4.2 V. [1] says “Charging voltage must be set 4.2V/cell.” and, allowing for charger tolerance, “lower than 4.25V/cell” (Proper use 1); “Do not use the continuous charging method.” (1.1); its safety instructions add “Do not maintain secondary batteries on charge when not in use.” (Danger 1.5).
  • 2.5 A is the standard charge, “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4. 15 A is the “Max. charging current” [1] §3.6, with no temperature, voltage, cut-off or charge time printed beside it. The 500-cycle rating charges at 6 A [1] §3.10, so it doesn’t cover charging at 15 A.
  • Charge between 0 and 45 °C ambient [1] §3.13; at the cell surface, 0 to 60 °C, with recharging recommended to resume below 45 °C [1] §3.14. Below 0 °C, don’t charge.
  • Below 2.0 V the cell has been over-discharged: [1] says “The cell should not be over-discharged below 2.0V.” (Proper use 2.3). For such a cell it asks for a pre-charge at “lower than 0.1C” (under 500 mA, our arithmetic) until the voltage is back above 2.0 V, then the standard charge, and says “If the cell voltage unable to reach in specified period/time, stop charging immediately.” It prints no time (Proper use 1.2).
  • [1] asks for a charger with timer, current detection and open-circuit voltage (OCV) detection, which stops once the cell is fully charged (Proper use 1.3).

Fig 5.1 plots values that [1]’s handling and pack design sections print as text; Tenpower draws no chart of them. They match the cell ratings: overcharge protection “below 4.25V/cell” against a 4.2 V charge voltage, and over-discharge protection at 2.5 V per cell, the §3.9 cut-off. [1] prints no charge-rate table, no charge-temperature table and no charge time, so this section has no capacity-by-charge figure.

06CYCLE LIFE AND STORAGE

What it keeps after use and storage.

[1] prints at least 60 % of the initial capacity after 500 cycles, and a capacity recovery of at least 90 % after 30 days at 60 ± 3 °C. Neither base is printed in mAh, so the page shows them as printed. [1] prints no cycle-life curve. Its storage clauses are listed one by one, with one line from the SDS [2]; where the SDS’s long-period storage conditions differ from [1], this page follows [1].

PRINTED IN [1]FIG 6.1

Capacity kept after cycling and storage

  • After 500 cycles 6 A charge, 40 A discharge to 2.5 V or 75 °C · % of “Initial capacity” [1] §3.10≥ 60 %
  • After 30 days at 60 ± 3 °C from the standard charge · recharged, then 10 A at 25 °C · basis not printed [1] §8.7≥ 90 %
  • Kept in ex-factory state below 30 % of charge, inside the §3.15 limits · % of standard discharge capacity, Note (*) [1]> 90 %

Percentages as printed in [1], each against its own base, none printed in mAh: the cell’s own initial capacity after 500 cycles (§3.10; §8.6 words it “retention of first cycle”), an unstated base for the §8.7 recovery, and the standard discharge capacity in Note (*), “more than 90%”. So no mAh is calculated. Orange: the cycle-life floor. A rating, not a warranty, and not a curve: [1] prints no capacity between cycle 1 and 500.

Storage, clause by clause

  • By storage time: “1 year: -20~25℃(*)”, “3 month : -20~45℃(*)”, “1 month: -20~60℃(*)” [1] §3.15 (fig 1.4), with Note (*): “If the cell is kept as ex-factory status (below 30% of charge), the capacity recovery rate is more than 90% of standard discharge capacity.”
  • The handling section prints the same ranges in its own words: “When stored within 1 month: -20°C ~ +60°C”; “When stored within 3 months: -20°C ~ +45°C”; “When stored within 12 months : -20℃ ~ +25°C” [1] Proper use 3.3.
  • Humidity “≤60%” [1] §3.16. “The cell should be stored in a dry area and no corrosive gas.” “No pressing on the cell.” [1] Proper use 3.1–3.2.
  • For 3 months or more: “it is strongly recommended that the cell is preserved at dry and low temperature.” [1] §13.1. Its Chinese line says “必须”, must.
  • Activation “once every three months”: a 0.2C CCCV charge to 4.2 V with a 0.01C cut-off, ten minutes’ rest, a 0.2C discharge to 2.5 V, ten minutes’ rest, then a 0.2C charge for three hours [1] §12. On the printed 1C, 0.2C is 1,000 mA and 0.01C is 50 mA (our arithmetic).
  • In a pack: “After the cell assembled in pack, the pack should be recharged to 30% SOC if the pack has never been used for one (1) year, prevent over low voltage.” [1] Proper use 3.4. Its Chinese line says to charge to “约30%”, about 30 %, once a pack has gone unused “超过1 年”, more than 1 year.
  • As shipped by Tenpower: “The cell should be shipped in 30% charged state.” Its Chinese line, Note (*) and §15 say below 30 %; the open-circuit voltage is 3.50–3.59 V within 90 days of Tenpower’s shipping date, at 15 to 30 °C [1] §8.8.
  • Separately, the SDS adds “Do not store together with oxidizing and acidic materials.” [2] Section 7. Its “Long period storage” conditions (Section 7) differ from [1]’s §3.15 and §3.16 limits, so this page follows [1] for storage.

07TRANSPORT TESTS

What the UN38.3 summary records.

UN38.3 is the set of transport tests, in section 38.3 of the UN Manual of Tests and Criteria, that a lithium cell must pass before it can be shipped. The UN38.3 Test Summary [3], 812500500174234, comes from Shanghai Institute of Chemical Industry Testing Co., Ltd., a testing company separate from the Tenpower company it names as consignor and manufacturer. For the INR21700-50XG it prints “合格 Passed” for T.1–T.6 and T.8, and “/” for T.7 and for 38.3.3 (f) and (g). It summarizes original test report No. 1125080720 (2025-09-24), was issued 2025-09-29, and names the standard ST/SG/AC.10/11/Rev.8; it prints no per-cell results, sample counts or test conditions. Its conclusion, spacing as printed: the samples “meet the requirements of test items of the UNITED NATIONS Manual of Tests and CriteriaST/SG/AC.10/11/Rev.8 38.3”. It covers the lab’s samples, consigned by Tenpower, not our lot.

UN38.3 results as printed in [3]
TEST, AS PRINTED [3] RESULT, AS PRINTED
T.1 高度模拟 Altitude simulation 合格 Passed
T.2 温度测试 Thermal test 合格 Passed
T.3 振动测试 Vibration 合格 Passed
T.4 冲击测试 Shock 合格 Passed
T.5 外部短路 External short circuit 合格 Passed
T.6 撞击 Impact 合格 Passed
T.7 过度充电 Overcharge /
T.8 强制放电 Forced discharge 合格 Passed
38.3.3 (f) /
38.3.3 (g) /
What the UN38.3 summary prints about the cell
ITEM AS PRINTED [3]
Summary 812500500174234, issued 2025-09-29
Original test report No. 1125080720, 2025-09-24; not on file
Test standard UNITED NATIONS Manual of Tests and Criteria 38.3, ST/SG/AC.10/11/Rev.8
Test lab 上海化工院检测有限公司 Shanghai Institute of Chemical Industry Testing Co., Ltd.
Consignor 天鹏锂能技术(淮安)有限公司 Huaian Tenpower Lithium Co., Ltd
Manufacturer 天鹏锂能技术(淮安)有限公司 Huaian Tenpower Lithium Co., Ltd
Type INR21700-50XG
Nominal voltage (V) 3.6
Capacity/energy 5000mAh
Mass (kg) 0.0666; 66.6 g, a unit conversion; [3] doesn’t say how many cells were weighed
Li content (g) /
Appearance 灰色塑料薄膜外壳 Gray plastic film shell

Safety tests the specification lists

Safety tests listed in the specification
TEST METHOD, CONDENSED FROM [1] PASS CRITERION, AS PRINTED SECTION
Vibration test Fully charged cell fixed to a vibration table and swept 10 Hz → 55 Hz → 10 Hz at 1 Hz per minute, in 90 to 100 minutes, along the cell’s axis and perpendicular to it. The English line prints “The total excursion of the vibration is 0.8mm (0.060 inches).”; the Chinese line prints “振幅为0.8mm(0.060 英寸)”, which calls it an amplitude (振幅). 0.060 inch is 1.524 mm, not 0.8 mm (our arithmetic); [1] doesn’t say which it means “There shall be no electrolyte leakage” [1] §9
Mechanical shock Shocks along X, Y and Z, at right angles to one another: a minimum mean acceleration of 75 g in the first 3 ms, with a peak between 125 g and 175 g. Its Chinese line adds that each shock is applied normal to the cell surface, and defines G as the local acceleration (当地加速度). Its Chinese criterion reads “不冒烟” (no smoke) where the English reads “No flame” “No leakage 、No flame、No fire、No explosion” [1] §9
Abnormal Charging Test Fully discharged cell overcharged at 3C (15,000 mA, our arithmetic: 3 × 5,000 mA) to 10 V, temperature monitored; the test ends when the cell is back at room temperature. Its Chinese name, 过充测试, means overcharge test “No fire and no explosion” [1] §10
Over-discharge Test After standard charge, discharged at 1C (5,000 mA, as [1] defines 1C) for 90 minutes “No fire and no explosion” [1] §10
Short-Circuit Test After standard charge, shorted at 20 ± 5 °C until the cell is back at ambient temperature. [1] prints the circuit limit as “(cross section of the wire or connector should be less than 100mΩ)”; its Chinese line gives a metal wire of no more than 100 mΩ “No fire and no explosion” [1] §10
Crush Test After standard charge, crushed between two flat surfaces, the cell’s long axis parallel to them, until the hydraulic ram reads 2,500 psig (17.2 MPa), a force of 3,000 pounds (13 kN); then released “No fire and no explosion” [1] §10
Heating Test After standard charge, in an oven with a thermocouple on the cell: heated from room temperature at 5 ± 2 °C per minute, then held 10 minutes once the oven reaches 130 ± 2 °C. Its Chinese name, 热冲击, means thermal shock “No fire and no explosion” [1] §10
Free falling (drop) Fully charged cell dropped three times onto a concrete floor, in random orientations, from a height printed “1, 0 m” (“1.0m” in the Chinese line) “No fire and no explosion” [1] §10

Tenpower’s own test methods and pass criteria, from “9. 机械特性Mechanical Characteristics” (§9) and “10. 安全特性Safety” (§10) of [1]: methods condensed in our words, test names and criteria as printed, with their own spacing and marks. [1] prints no results and no sample counts, and names no test standard. Their currents and voltages, such as 3C to 10 V in the abnormal charging test, are abuse conditions, not ratings. Where the English and Chinese lines differ in substance, both are given. The UN38.3 results above are a different set of tests, from [3]: [1]’s vibration and shock methods are Tenpower’s own, not [3]’s T.3 and T.4.

This description cites the SDS [2] and the UN38.3 summary [3] rather than linking them: both print a person’s telephone number and email address, which this description doesn’t reproduce. Call or text with questions about either.

08COMPARE

Where the 50XG sits.

Sixteen other 21700 cells, each from its own data sheet [4]. The 50XG’s 90 A holds only “(with 75℃ temperature cut-off)”; pulse figures aside, no other sheet in the set prints a discharge figure that high, with or without a cut-off. Without the cut-off, [1] §3.7 prints 40 A, and eight sheets print a higher continuous or maximum figure, six of them only with a temperature cut-off. Three print a higher minimum capacity than its 4,950 mAh: the Samsung 58E and the Tenpower 60XG, both drafts, and the Molicel M65A, preliminary R&D data. The conditions behind each figure differ, so the table quotes each sheet’s wording.

DATA SHEETS · [1][4]FIG 8.1

Minimum capacity and discharge, side by side

  • Tenpower 50XG INR21700-50XG4,950 mAh minimum · 5,000 nominal90 A max. continuous · 75 °C temp. cut-off; 40 A without
  • EVE 40PL INR21700/40PL4,000 mAh minimum · no typical printed70 A maximum, not continuous · with temperature cut-off, 75 °C recommended, 80 °C max.
  • Tenpower 60XG INR21700-60XG5,900 mAh minimum · 6,000 nominal60 A max. continuous · 75 °C temp. cut-off; 40 A without; draft
  • Molicel P50B INR-21700-P50B4,850 mAh minimum · 5,000 typical60 A continuous · 80 °C cut-off
  • Samsung 45T CC4503F1014,400 mAh minimum · 4,500 typical50 A continuous · 80 °C temp. cut; 35 A without
  • Samsung 50S INR21700-50S4,800 mAh rated minimum at 10 A · 5,000 typical45 A continuous · 80 °C temp. cut; 25 A without
  • Molicel P45B INR-21700-P45B4,350 mAh minimum · 4,500 typical45 A max. continuous · no condition printed
  • Samsung 40T INR21700-40T4,000 mAh minimum · no typical printed45 A continuous · 80 °C temp. cut; 35 A without
  • Molicel P42A INR-21700-P42A4,000 mAh minimum · 4,200 typical45 A continuous · no condition printed
  • Sony/Murata VTC6A US21700VTC6A4,000 mAh minimum · 4,160 nominal40 A continuous max. · 80 °C temp. cut
  • Molicel M65A 21700-M65A6,400 mAh minimum · 6,500 ± 70 mAh at 0.2C, no typical or nominal label printed25.6 A rating type not printed · 90 °C cut-off; preliminary
  • EVE 50E INR21700/50E4,900 mAh minimum · 5,000 nominal15 A max. continuous · no condition printed
  • Molicel M50A INR-21700-M50A4,800 mAh minimum · 5,000 typical15 A continuous · no condition printed
  • Samsung 50G INR21700-50G (Ver. B)4,900 mAh minimum · no typical printed14.7 A for continuous discharge · −20 to 30 °C; 9.8 A at 31 to 60 °C
  • LG M50LT INR21700M50LTMinimum not stated by manufacturer · no mAh capacity printed; 1C = 4,800 mA14.4 A max. · 10 to 25 °C; 7.2 A at 25 to 55 °C, 2.4 A at −20 to 10 °C
  • Samsung 58E CC5493F101 (Ver. A)5,330 mAh minimum · no typical printed10.66 A 2C for continuous discharge · 10.66 A = 2 × 5,330 mA, our arithmetic
  • Samsung 50E INR21700-50E4,900 mAh minimum · no typical printed9.8 A for continuous discharge · no condition printed

Each cell’s figures copied from its own data sheet [1][4]. Bars start at zero: minimum capacity on a 0–7,000 mAh scale, discharge on 0–90 A. The condition sits beside each current; where a sheet prints two continuous figures, the bar shows the higher and the condition names the other. The EVE 40PL’s 70 A is printed as a “Maximum Discharge” with a temperature cut-off, not as continuous; the Samsung 58E’s 10.66 A is our arithmetic from 2C; the Samsung 50S’s 4,800 mAh is its rated minimum at 10 A, not a 0.2C minimum; the Molicel M65A sheet is preliminary R&D data. Orange: the 50XG. Pulse figures are left out; a figure printed as a maximum, not as continuous, is shown with its printed wording (EVE 40PL).

Comparison cells, ratings as printed
CELL TYPICAL OR NOMINAL mAh MINIMUM mAh DISCHARGE AS PRINTED CHARGE RATING AS PRINTED MASS g
Tenpower 50XG
INR21700-50XG
5,000 nominal 4,950 “Max. continuous discharge current”: “40A (without temperature cut off)” / “90A(with 75℃ temperature cut-off)” (whether the 75 °C is a cell-surface or an ambient temperature is not printed; the pulse figure is not shown) “Max. charging current”: “15A” (no condition printed); standard charge “CCCV, 2.5A, 4.2V, 100mA cut-off” 71.0 max
EVE 40PL
INR21700/40PL
not printed 4,000 “Maximum Discharge”: “70A(17.5C), 2.50V”, “With Temperature Cut-off”, “TRecommended: 75℃”, “TMax: 80℃” (printed as a maximum, not as continuous; the basis of the cut-off temperature is not printed) “Maximum Charge”: “8.0A(2.0C), 4.20±0.05V, CCCV 0.1A cut-off” 67.0 max
Tenpower 60XG
INR21700-60XG
6,000 nominal 5,900 “Max. continuous discharge current”: “40A (without temperature cut off)” / “60A(with 75℃ temperature cut-off)” (a draft sheet; whether the 75 °C is a cell-surface or an ambient temperature is not printed; the pulse figure is not shown) “Max. charging current”: “16A” (no condition printed; a draft sheet) 76.0 max
Molicel P50B
INR-21700-P50B
5,000 typical 4,850 “Discharge Current, Continuous: 60 A (80°C cut-off)” “Charge Current, Maximum: 25 A (70°C cut-off)” 71 max
Samsung 45T
CC4503F101
4,500 typical 4,400 “Max. continuous discharge (Surface temperature): 35A(Without temperature cut) / 50A(With 80℃ temperature cut)” “Max. charge current: 9A (for step charge) / 6A (continuous charge)” 72.0 max
Samsung 50S
INR21700-50S
5,000 typical 4,800 rated minimum at 10 A “Max. continuous discharge (Surface temperature): 25A(Without temperature cut) / 45A(With 80℃ temperature cut)” “Max. charge current: 6A (continuous charge)” 72.0 max
Molicel P45B
INR-21700-P45B
4,500 typical 4,350 “Maximum continuous discharging current: 45A” (no condition printed; remark: “Cycle life is reduced at high rates.”) “Maximum continuous charging current: 9A” (remark: “High rate charge cycle will decay fast.”) 70 max
Samsung 40T
INR21700-40T
not printed 4,000 “Max. continuous discharge (Surface temperature): 35A(Without temperature cut) / 45A(With 80℃ temperature cut)” “Rated charge: CCCV, 6A, 4.20 V, 100mA cut-off” (this spec prints no separate max. charge current item) 70.0 max
Molicel P42A
INR-21700-P42A
4,200 typical 4,000 “Discharge Current, Continuous: 45 A” (no condition printed) not printed on the Version 1.7 sheet (“Charge Current, Standard: 4.2 A”); Doc # INR21700P42A-01 Rev. 0.2: “Maximum charging current: 8.4A” 70 max
Sony/Murata VTC6A
US21700VTC6A
4,160 nominal 4,000 “Continuous Maximum Discharging Current: 40A (With 80deg.C temperature cut)” “Maximum Charging Current: 6A (Continuous)” not printed placeholder “xx ±1.5g”
Molicel M65A
21700-M65A
6,500 ± 70 at 0.2C; no typical or nominal label printed 6,400 “Discharge current: 25.6A (90℃cut-off)” (the word continuous is not printed; preliminary R&D data) “Charge current: 6.5A (Standard) / 6.5A (Max)” 72.5 ± 1.5, as printed
EVE 50E
INR21700/50E
5,000 nominal 4,900 “Max Continuous Discharge current”: 15,000 mA (no condition printed) “Max. Continuous Charge current” 2,500 mA (§5.9); “≤5000mA” in its charging-temperature row, 15 to 50 °C (§5.12); “Charge rates greater than 5000mA are not recommended.” (§12.2.1 b) 69.0 ± 2.0, as printed; no maximum printed
Molicel M50A
INR-21700-M50A
5,000 typical 4,800 “Discharge Current, Continuous: 15 A” (no condition printed) not printed on the V3 sheet (“Charge Current, Standard: 2.5 A”); Doc # INR21700M50A-01 Rev. 0.1: “Maximum charging current: 5.0A” 70 max
Samsung 50G
INR21700-50G (Ver. B)
not printed 4,900 “Max. Discharge Current (*²): 3C (14,700mA, for continuous discharge @ -20℃~30℃) / 2C (9,800mA, for continuous discharge @ 31℃~60℃)” “Max. Charge Current: 4,900mA (not for cycle life)” 71 max
LG M50LT
INR21700M50LT
not printed 1C = 4,800 mA Not stated by manufacturer “Max. Discharge Current (complete full charge)²⁾: -20 ~ 10℃ 0.5C (2,400mA) / 10 ~ 25℃ 3.0C(14,400mA) / 25 ~ 55℃ 1.5C(7,200mA)” (the sheet’s note 2 calls these the maximum continuous currents) “Max. Charge Current (complete full charge)²⁾: 0 ~ 25℃ 0.3C (1,440mA) / 25 ~ 45℃ 0.7C (3,360mA)” 68.2 ± 1.0, with tube and washer
Samsung 58E
CC5493F101 (Ver. A)
not printed 5,330 “Max. Discharge Current (*²): 2C (for continuous discharge)” (the sheet prints 1C = 5,330 mA, so 10.66 A is our arithmetic; non-continuous figure not shown) “Max. Charge Current: 1C (not for cycle life)” (1C = 5,330 mA as printed) 74 max
Samsung 50E
INR21700-50E
not printed 4,900 “Max. Discharge Current: 9,800mA (for continuous discharge)” (non-continuous figure not shown) “Max. Charge Current: 4,900mA (not for cycle life)” 69.5 max

Text in quotation marks is copied as printed from each manufacturer data sheet [1][4], newest version in our files, checked by a second reading; notes in parentheses are ours. The [4] sheets are quoted, not linked: several are marked confidential, draft, tentative or preliminary, as Sources notes beside each version. The Samsung 50E and the EVE 50E are different cells from different makers, and the Tenpower 60XG is a different cell from the 50XG. Links go to the bare-cell listing in our store; cells without a link aren’t listed there.

09PACK MATH

From one cell to a pack.

How the single-cell ratings scale in series (S) and parallel (P). Illustrative arithmetic, not a pack rating.

V MAX4.2 × Scharge voltage, 4.2 V [1] §3.4
V NOMINAL3.6 × Snominal voltage, 3.6 V [1] §3.5
CAPACITY5.0 × PAh at the 5,000 mAh nominal capacity; 4.95 × P at the 4,950 mAh minimum; 0.2C to 2.5 V [1] §3.1–3.2
CONTINUOUS40 × PA, “(without temperature cut off)”; 90 × P only “(with 75℃ temperature cut-off)” [1] §3.7*
Pack arithmetic by configuration
CONFIG CELLS V MAX V NOMINAL Ah, 5,000 mAh NOMINAL Ah, 4,950 mAh MINIMUM Wh, 18 Wh × S × P, SDS [2] CONTINUOUS A, 40 A × P, WITHOUT CUT-OFF* CONTINUOUS A, 90 A × P, 75 °C CUT-OFF* CELL MASS g, MAX
1S1P 1 4.2 3.6 5.00 4.95 18 40 90 71.0
2S1P 2 8.4 7.2 5.00 4.95 36 40 90 142.0
3S1P 3 12.6 10.8 5.00 4.95 54 40 90 213.0
4S1P 4 16.8 14.4 5.00 4.95 72 40 90 284.0
2S2P 4 8.4 7.2 10.00 9.90 72 80 180 284.0
3S2P 6 12.6 10.8 10.00 9.90 108 80 180 426.0
4S2P 8 16.8 14.4 10.00 9.90 144 80 180 568.0
7S3P 21 29.4 25.2 15.00 14.85 378 120 270 1,491.0
10S3P 30 42.0 36.0 15.00 14.85 540 120 270 2,130.0
10S4P 40 42.0 36.0 20.00 19.80 720 160 360 2,840.0
13S4P 52 54.6 46.8 20.00 19.80 936 160 360 3,692.0
14S5P 70 58.8 50.4 25.00 24.75 1,260 200 450 4,970.0
CALCULATED FROM [1]FIG 9.1

Continuous current ceiling, by parallel count

40 A × P, “(without temperature cut off)”90 A × P, only “(with 75℃ temperature cut-off)”
  • 1P 5.0 Ah nominal40 A90 A with the 75 °C cut-off
  • 2P 10.0 Ah nominal80 A180 A with the 75 °C cut-off
  • 3P 15.0 Ah nominal120 A270 A with the 75 °C cut-off
  • 4P 20.0 Ah nominal160 A360 A with the 75 °C cut-off
  • 5P 25.0 Ah nominal200 A450 A with the 75 °C cut-off
  • 6P 30.0 Ah nominal240 A540 A with the 75 °C cut-off

40 A × P and 90 A × P: the single-cell figures of [1] §3.7 times the parallel count; our arithmetic. Orange: “40A (without temperature cut off)”. White: “90A(with 75℃ temperature cut-off)”, which needs that cut-off in the pack. A ceiling before derating, not a pack rating.

* 40 A × P and 90 A × P multiply the single-cell figures in [1] §3.7, “40A (without temperature cut off)” and “90A(with 75℃ temperature cut-off)”, by the number of cells in parallel. [1] doesn’t say whether the 75 °C is the cell’s temperature or the air’s, or how long 90 A can run before the cut-off acts, so plan a pack on 40 A per cell. A pack sized on 90 A per cell needs a cut-off that stops the discharge at 75 °C, with its sensor on the hottest cell as the cautious choice, and that cut-off can end a discharge before the pack is empty. [1]’s only cycle-life figure is at 40 A with “2.5V or 75℃ cut-off” (§3.10); it prints none at 90 A. Wh = 18 Wh × S × P, using the 18 Wh the SDS prints with no condition [2] Section 1 (3.6 V × 5,000 mAh = 18.0 Wh, our check); [1] prints no Wh. [1] gives discharge temperatures of −20 to 60 °C ambient (§3.13) and −20 to 80 °C at the cell surface (§3.14). Derate for heat, size the BMS, fusing and interconnects for the derated current, and use matched cells of one model and lot. [1]’s pack design section asks for overcharge protection “below 4.25V/cell”, over-discharge protection at 2.5 V per cell with a consumption current below 1 µA, and anti-static, waterproof pack design. Mass counts cells only, at the printed 71.0 g max each. The UN38.3 summary [3] covers the INR21700-50XG cell, not your pack: a pack you build needs its own UN38.3 testing before it ships (section 07).

10SIZE AND FIT

Ø21.50 × 70.50 mm at most.

Drawn at its printed limits, “Diameter : ≤21.50mm” and “Height : ≤70.50mm” [1] §3.12, beside nominal 18650 and 21700 outlines. [1] prints these limits only, with no nominal size or tolerance, and doesn’t say whether they include the sleeve. Check tight holders against the 21.50 mm and 70.50 mm limits.

RATED · [1]FIG 10.1

Drawn to scale

18650nominal21700nominal50XG≤ 70.50 mmheight [1]≤ 21.50 mmdiameter [1]

All outlines drawn to the same scale. The 50XG at its printed limits [1]; the other outlines are nominal format sizes, for scale only. A plain outline: [1]’s Fig. 1 names no terminal style.

Dimensions
DIMENSION VALUE CONDITION
Diameter ≤ 21.50 mm “Diameter : ≤21.50mm” [1] §3.12; “Diameter≤21.50mm”, Fig. 1
Height ≤ 70.50 mm “Height : ≤70.50mm” [1] §3.12; “Height≤70.50mm”, Fig. 1
Mass 71.0 g “71.0g max” [1] §3.11
No-weld zone Not stated Not stated by manufacturer: [1] prints no prohibited welding area
Terminal Not stated Not stated by manufacturer: [1] names no terminal style
Volume 25.6 cm³ π × (21.50 mm ÷ 2)² × 70.50 mm ≈ 25,595 mm³, at the printed limits; a plain cylinder

Check that your holder or device takes a cell 70.50 mm long and 21.50 mm across, the limits printed in [1]. Spot-weld nickel strip; don’t solder to the cell: “Do not solder onto a cell in order to avoid damage on the cell.” [1] Proper use 6.4.

11USE IT RIGHT

Keep it inside its ratings.

What this cell is, and how to use it within its ratings.

  • This is a bare cell: a component for protected packs and devices built for it. It is not a standalone consumer battery and not for vaping.
  • [1] names no terminal style: check that your device takes a cell 70.50 mm long and 21.50 mm across, the limits printed in [1] §3.12.
  • Charge on a lithium-ion (Li-ion) charger that stops at 4.2 V. Stop discharging at 2.5 V [1].
  • Stay inside the ratings: discharge at no more than 40 A “(without temperature cut off)”, or 90 A only “(with 75℃ temperature cut-off)”, where something stops the discharge at 75 °C [1] §3.7, between −20 and 60 °C ambient (§3.13). Charge at the 2.5 A standard charge (§3.4) between 0 and 45 °C ambient. [1] also prints a 15 A “Max. charging current” with no condition (§3.6).
  • Spot-weld nickel strip; don’t solder to the cell (Proper use 6.4).
  • Replace a torn wrap before use. Carry cells in a case, never loose.
  • For packs: [1] asks for overcharge protection below 4.25 V per cell, over-discharge protection at 2.5 V per cell, a low consumption current in storage, anti-static and waterproof pack design, and a check of voltage and internal impedance before use (Proper use 5–6). Use matched cells of one model and lot, and add fusing sized for the pack.

Questions? Call 1-800-547-3050 or text 1-833-419-2192 to ask a person.

Documents

We hold three documents for this cell; this description links none of them. The specification [1], Version No. V0.2, Effective Date 2025/08/14, is marked “TENPOWER confidential proprietary” on every page, with a Chinese footer that limits it to customers’ internal use. The SDS [2], Report No. 2026TP0350XGSDS, Issue Date 2026-01-01, and the UN38.3 test summary [3], 812500500174234, issued 2025-09-29, print a person’s telephone number and email address, which this description doesn’t reproduce. This description quotes all three and cites each by its printed number and date. Call or text with questions about any of them. Not on file: Rev. 0.1 of [1], and the full UN38.3 test report that [3] summarizes.

Ships from Stockbridge, GA. Most in-stock orders ship within 1 business day.

12QUESTIONS

Questions, answered.

Short answers. Where an answer comes from a document, it carries its source; the rest is standard handling practice. Anything else: call 1-800-547-3050 or text 1-833-419-2192.

Is the 50XG a protected cell?

We list it as a bare cell: a component for protected packs and devices built for it. [1] prints no protection status for the cell itself; it puts overcharge and over-discharge protection in the battery pack (Proper use 5.2–5.4). Use it only in packs with a battery management system (BMS) or in devices built for bare cells.

Which documents are these figures from?

Every rating for the 50XG on this page comes from one document, Tenpower’s “PRODUCT SPECIFICATION” for model INR21700-50XG, Version No. V0.2, Effective Date 2025/08/14 [1], except the energy figure: only the safety data sheet (SDS) [2] prints one, “18 Wh”, under “Ratings/额定参数”. The C-rates, mAh, runtimes and volume are our arithmetic on [1]. It is the only version of [1] we hold; its history record lists an earlier Rev. 0.1, dated “25/5/8”, which we don’t hold, and one change in Rev. 0.2: “重量Weight: 75g max” to “重量Weight: 71g max”. Because it is marked “TENPOWER confidential proprietary”, this description quotes it rather than linking it. The cathode material, the transport entries and one storage line also come from the SDS [2], and the transport-test results from the UN38.3 test summary [3]. We haven’t checked our own cells against any of them (section 13).

Is it a 5,000 mAh cell?

Nominally, yes: [1] prints 5,000 mAh as its “Nominal capacity” and 4,950 mAh as its “Minimum Capacity”, both with the same printed condition, “Charge: 0.5C(2.5A), 4.2V, 100mA cut-off” and “Discharge: 0.2C(1000mA), 2.5V cut-off” [1] §3.1–3.2. It doesn’t call either figure typical. At higher currents it delivers less: 93 % of 4,950 mAh, about 4,604 mAh, at 40 A (§8.4, fig 3.1). The SDS prints “3.6V, 5000mAh, 18 Wh” under “Ratings/额定参数” [2], and the UN38.3 summary prints “5000mAh” [3], both with no condition.

Is it a 90 A cell?

Only with a temperature cut-off. [1] §3.7 prints two continuous figures: “40A (without temperature cut off)” and “90A(with 75℃ temperature cut-off)”. 90 A holds only where something stops the discharge at 75 °C: in a pack, a temperature sensor read by the BMS; in a device, its own temperature cut-off. [1] doesn’t say whether the 75 °C is the cell’s temperature or the air’s, or how long 90 A can run before the cut-off acts, so a 90 A discharge can end at 75 °C before the cell is empty. Its rate table stops at 50 A (92 % of the 4,950 mAh index), and its only cycle-life rating is at 40 A, with a “2.5V or 75℃ cut-off” (§3.10); it prints none at 90 A. If you don’t know whether your pack or device has that cut-off, plan for 40 A per cell. [1] also prints a pulse figure with a 3-second duration and no other condition; we publish continuous ratings only, so we leave it out.

How fast can I charge it?

The standard charge is 2.5 A: “CCCV, 2.5A, 4.2V, 100mA cut-off” [1] §3.4, 0.5C on the printed 1C of 5,000 mA. [1] prints no charge time, at 2.5 A or at 15 A. The “Max. charging current” is “15A” [1] §3.6, with no temperature, voltage or cut-off printed beside it. The 500-cycle rating charges at 6 A [1] §3.10, so it doesn’t cover charging at 15 A. Charge between 0 and 45 °C ambient [1] §3.13; at the cell surface, 0 to 60 °C, with recharging recommended to resume below 45 °C [1] §3.14.

What charger should I use?

A lithium-ion charger with a CC-CV profile (constant current, then constant voltage) that stops at 4.2 V. [1] says “Charging voltage must be set 4.2V/cell.” and, allowing for charger tolerance, “lower than 4.25V/cell”, and asks for a charger with timer, current detection and open-circuit voltage (OCV) detection that stops once the cell is full (Proper use 1, 1.3). Not a NiMH, LiFePO4 or lead-acid charger.

How long will it run at my current?

Runtime ≈ capacity ÷ current. Calculated from the capacities in [1] §8.4, after a standard charge: about 4 h 57 min at 0.2C (1,000 mA), 27.9 min at 10 A, 9.4 min at 30 A and 6.9 min at 40 A (fig 3.2). For your own draw, divide the capacity in fig 3.1 at the nearest printed current by your current in mA to get hours. 4,950 mAh applies at 0.2C (1,000 mA); from 10 to 50 A, [1] §8.4 prints 92 to 95 % of it. Expect less in the cold: at −20 °C, [1] §8.5 prints 90 % of the capacity at 25 °C for a 30 A discharge (fig 4.1).

How does cold affect it?

At −20 °C, the bottom of its discharge range, the table in [1] §8.5 prints 90 % of the capacity at 25 °C for a 30 A discharge to 2.5 V; 92 % at −10 °C and 95 % at 0 °C. [1] prints no mAh for that 25 °C capacity, so we don’t convert these to mAh. At 60 °C it prints 100 %, the same as at 25 °C. [1] prints no capacity after a cold charge; don’t charge below 0 °C.

How many cycles will it last?

The specification prints “Capacity≥60% Initial capacity@500 cycles”, with “Charge: 6A, 4.2V, CCCV 100mA cut-off @RT” and “Discharge: 40A, 2.5V or 75℃ cut-off @RT” [1] §3.10. Its test section words it as 60 % “retention of first cycle” after 500 cycles at 25 ± 3 °C, with 10-minute and 45-minute rests [1] §8.6. [1] prints no mAh for the initial capacity, so we don’t convert the 60 % to mAh, and it gives no figure for other currents or temperatures. Heat, current, depth of discharge and storage all change the result.

What chemistry is it?

Lithium-ion: [1] describes it as a “Cell (lithium-ion rechargeable cell)” (§2) and names no cathode material. The SDS lists “lithium nickel cobalt manganess oxides” (镍钴锰酸锂; “manganess” as printed), CAS 182442-95-1, with “35.94%” printed beside it [2] Section 3. None of the three documents prints a cathode abbreviation, so we don’t use one, and we don’t infer one from the model code.

Is there an SDS or a UN38.3 test report?

We hold the SDS and a UN38.3 test summary, not the full test report; this description links neither. The safety data sheet (SDS) [2], Report No. 2026TP0350XGSDS, Issue Date 2026-01-01, is compiled by Tenpower; it gives the energy figure, the cathode material, the transport entries and the one storage line this page quotes. The UN38.3 test summary [3], 812500500174234, issued 2025-09-29 by Shanghai Institute of Chemical Industry Testing Co., Ltd., a separate testing company, prints “合格 Passed” for T.1–T.6 and T.8 and “/” for T.7 (section 07). The full report it summarizes, No. 1125080720 (2025-09-24), is not on file. The SDS and the summary both print a person’s telephone number and email address, which this description doesn’t reproduce, so it cites them by number and date instead. Neither prints a version or a validity date. If you need either document to ship cells or packs, call or text before you order.

How does it ship?

The SDS prints “UN3480 or UN3481” (UN3480: cells shipped on their own; UN3481: cells packed with or inside equipment). By air, it cites Packing Instruction 965, Section IB, with Class 9, or Packing Instructions 966–967, Section II, with the class “Not applicable”, under the “2026 IATA Dangerous Goods regulations 67th Edition”. Those section numbers follow its Chinese air line (第IB部分, 第II部分). Its English packing line prints 965 as “Section 1B” and 966-967 as “Section Il”, and its class line prints “Class 9(PI965 Section 1B) or Not applicable (PI966 -967 Section I)”, with “Section I” for 966–967. The SDS does not say which is meant, so check the current regulations. By sea: “not restricted according to IMOIMDG Code (inc. Amendment 42-24)Special Provision188”, spacing as printed [2] Section 14. Those are the editions the SDS cites (Issue Date 2026-01-01); the regulations are revised regularly, so check the current edition before you ship cells yourself. The UN38.3 test summary [3] covers the INR21700-50XG cell; a pack built from these cells needs its own UN38.3 testing.

Can I use it in a vape or e-cigarette?

No. It is a bare cell: a component for protected packs and devices built for it, not for vaping. [1], [2] and [3] have no clause on vaping; this is our own rule for bare cells.

Can I solder to it?

No. [1] says “Do not solder onto a cell in order to avoid damage on the cell.” (Proper use 6.4). Spot-weld nickel strip. [1] prints no prohibited welding area for this cell.

Can I mix 50XG cells with other cells?

No, not in the same pack. [1] says “Do not mix our batteries with other battery brands or batteries of a different chemistry such as alkaline and zinc carbon.” and “Do not mix new batteries in use with semi-used batteries, over-discharge may occur.” (Warning 1.3–1.4). Use cells of the same model and lot, at the same state of charge. In series, the weakest cell reaches 2.5 V first and limits the whole pack.

How should I store spare cells?

In a case, away from metal objects, somewhere dry and cool. [1] allows storage at −20 to 25 °C for 1 year, −20 to 45 °C for 3 months and −20 to 60 °C for 1 month (§3.15; its handling section prints the same ranges), with humidity “≤60%” (§3.16). For 3 months or more it recommends that the cell be kept “dry and low temperature” (§13.1), and it asks for an activation routine “once every three months” (§12; section 06). The SDS adds “Do not store together with oxidizing and acidic materials.” [2] Section 7. [1] says cells leave Tenpower at 30 % charge or below, at 3.50–3.59 V open-circuit within 90 days of its shipping date, at 15 to 30 °C (§8.8, §15). We haven’t checked our own stock against that; [1] asks you to inspect voltage and internal impedance before using a cell (Proper use 6.3).

13SOURCES

Sources and method.

Where every number on this page comes from.

  • + Source: [1] Huaian Tenpower Lithium Co., Ltd, “PRODUCT SPECIFICATION” (Chinese title “锂离子电芯规格书”), “RECHARGEABLE LITHIUM ION CELL”, Model Name INR21700-50XG, Spec. No. INR21700-50XG, Version No. V0.2, Effective Date 2025/08/14 (as printed); 19 pages, in Chinese and English; marked “TENPOWER confidential proprietary” on every page, with a Chinese footer that calls it a confidential Tenpower document for customers’ internal use only; not marked draft; its history record lists Rev. 0.1 (“25/5/8”) and Rev. 0.2 (“25/8/10”); on file; quoted in this description, not linked from it, because it is marked confidential. Call or text with questions about it.
  • + Source: [2] HUAIAN TENPOWER LITHIUM CO., LTD. (天鹏锂能技术(淮安)有限公司), “Safety Data Sheet” (“安全技术说明书”), Report No. 2026TP0350XGSDS, Sample Name “RECHARGEABLE LITHIUM ION CELL”, Model INR21700-50XG; Issue Date 2026-01-01 (as printed); no version, effective date or validity printed; 10 pages, in English and Chinese; applicant, manufacturer and compiling unit “HUAIAN TENPOWER LITHIUM CO., LTD.”; no confidential, proprietary, draft or tentative marking; on file; cited in this description, not linked from it, because it prints a person’s telephone number and email address, which this description doesn’t reproduce.
  • + Source: [3] Shanghai Institute of Chemical Industry Testing Co., Ltd. (上海化工院检测有限公司), “UN38.3 Test Summary” 812500500174234, “Lithium-ion Rechargeable Cell”, Type INR21700-50XG; no version printed; issued 2025-09-29; it summarizes original test report No. 1125080720, dated 2025-09-24, which is not on file; test standard “UNITED NATIONS Manual of Tests and Criteria 38.3”, ST/SG/AC.10/11/Rev.8; consignor and manufacturer “天鹏锂能技术(淮安)有限公司 Huaian Tenpower Lithium Co., Ltd” (as printed); the lab is a separate company from Tenpower; 2 scanned pages, read from the page images; on file; cited in this description, not linked from it, because it prints the same telephone number and email address as [2].
  • + Company names as printed: in [1], “Huaian Tenpower Lithium Co., Ltd” and “天鹏锂能技术(淮安)有限公司” on the cover; “HUAIAN TENPOWER LITHIUM Co., Ltd.” in §1; “Huaian Tenpower Lithium Co., Ltd.” in the handling and safety sections, whose Chinese lines print “江苏天鹏电源提供” and “江苏天鹏电源有限公司”; “TP (Trade name of Tenpower)” in §5.3. In [2], “HUAIAN TENPOWER LITHIUM CO., LTD.” and “天鹏锂能技术(淮安)有限公司”. In [3], “天鹏锂能技术(淮安)有限公司 Huaian Tenpower Lithium Co., Ltd” as consignor and manufacturer, and “上海化工院检测有限公司 Shanghai Institute of Chemical Industry Testing Co., Ltd.” as test lab.
  • + Source: [4] Samsung 40T: INR21700-40T data sheet, Spec. No. INR21700-40T, Version No. 0.0, December, 2017 (headed “SAMSUNG SDI Confidential Proprietary”; every page watermarked “Tentative”; no version suffix); on file
  • + Source: [4] Samsung 45T: CC4503F101 data sheet, Spec. No. CC4503F101, Version No. V0.1 (Draft), Date of Application 24/02/01; marked confidential; on file
  • + Source: [4] Samsung 50E: INR21700-50E data sheet, Spec. No. INR21700-50E, Version No. V1.0 (General Version), 2018/07/11; marked confidential; on file
  • + Source: [4] Samsung 50G: INR21700-50G (Ver. B) data sheet, Spec. No. INR21700-50G, Version No. Draft V0.2, Date of Application 2023/05/10; on file
  • + Source: [4] Samsung 50S: INR21700-50S data sheet, Spec. No. INR21700-50S, Version No. V1.0, Date of Application 2021/04/19; marked confidential; on file
  • + Source: [4] Samsung 58E: CC5493F101 (Ver. A) data sheet, Spec. No. CC5493F101, Version No. Draft V0.1, Date of Application 2023/12/04; marked confidential; on file
  • + Source: [4] Molicel P42A: INR-21700-P42A data sheet, Product Data Sheet Version: 1.7; max charge from Doc # INR21700P42A-01, Rev. 0.2, 8/17/2018; on file
  • + Source: [4] Molicel P45B: INR-21700-P45B data sheet, Doc # INR21700P45B-01, Rev. 0.2, 2022/01/06 (Approval Sheet (tentative)); on file
  • + Source: [4] Molicel P50B: INR-21700-P50B data sheet, Product Data Sheet Version 1.1; on file
  • + Source: [4] Molicel M50A: INR-21700-M50A data sheet, Product Data Sheet, no version printed (file INR21700M50A-V3-80097, PDF dated 2020-04-01); max charge from Doc # INR21700M50A-01, Rev. 0.1, 6/4/2019; on file
  • + Source: [4] Molicel M65A: 21700-M65A data sheet, R&D Update, M65A performance (preliminary); no version printed (file dated 2025.04.29); on file
  • + Source: [4] LG M50LT: INR21700M50LT data sheet, Doc No. 2021-LSD-MBD-b00002, Rev 2, 2021-07-06 (“For (Promotion) only”; marked “This document is NOT final version”); on file
  • + Source: [4] Sony/Murata VTC6A: US21700VTC6A data sheet, Tohoku Murata Spec. No. KU※※※※※, Ver. 0.1, 1st issue 2017.11.27 (Products Information, Tentative); on file
  • + Source: [4] EVE 40PL: INR21700/40PL data sheet, Spec. No. PBRI-INR21700/40PL-D06-01, Version No. A, June, 2023; marked confidential and proprietary; on file
  • + Source: [4] EVE 50E: INR21700/50E data sheet, Document No. RD-EVE INR21700/50E-S76-LF, Edition A (initial release), Effective Date 2022.5.23; on file
  • + Source: [4] Tenpower 60XG: INR21700-60XG data sheet, Spec. No. INR21700-60XG, Version No. V0.1 draft, Effective Date 2025/12/09 (draft; every page marked TENPOWER confidential proprietary); on file
  • + Method: none of [1], [2] or [3] prints a performance chart; [1] prints two relative-capacity tables, §8.4 by current and §8.5 by temperature. Every chart on this page plots a figure printed in [1]–[4], or arithmetic on those figures with the formula under it, except the nominal 18650 and 21700 outlines in fig 10.1, drawn for scale only; no line is drawn between printed points. C-rates for currents [1] prints in amps are the current ÷ the printed 1C of 5,000 mA; mA for the currents it prints as C-rates are the C-rate × 5,000 mA. mAh from a printed percent = percent × 4,950 mAh, rounded half up, for §8.4 only, whose 100 % index is printed in mAh. [3] is a scan with no text layer; its entries were read from the page images. Each figure was copied from the document and checked against it by a second reading.
  • + Not shown from [1]: its §3.8 pulse discharge figure, printed with a 3-second duration and no other condition, because we publish continuous ratings only; its warranty clauses (§11), which are written to Tenpower’s direct customer, and its §13.2 clause on matters to be agreed between Tenpower and that customer; its cell-marking key (§5), whose example date code is printed “UC102” in the text and “UC103” in the marking drawing above it, an example, not a lot code of the cells we stock; its packing section (§14), which prints only “TBD”; the names and telephone number on its cover; and the rest of its safety instructions, beyond the clauses quoted here.
  • + Not shown from [2]: its hazard description (Section 2); its other Section 3 ingredients beyond the cathode line; Sections 4–13 apart from the one storage line quoted here, including its appearance line (Section 9), which doesn’t match [3]’s, its advice to recharge periodically (Section 7), which [1]’s activation routine already covers, and its “Long period storage” conditions (Section 7), which differ from [1]’s storage clauses, so this page follows [1] for storage; its regulatory notes (Section 15); and its contact details and the name of its compiler.
  • + Not shown from [3]: the contact details in its consignor and manufacturer rows, its signatory, and its sample photographs.
  • + Not on file: Rev. 0.1 of [1], listed in its history record; the full UN38.3 test report No. 1125080720 that [3] summarizes.
  • + Not shown: results from our own lot. We will add them only once our incoming-inspection procedure is published, with sample size, instrument and date.

Recently viewed